JUNCTION BOX, MICROINVERTER
AND TERMINALS
Modules equipped with one junc-
tion box contain terminals for both
positive and negative polarity, and
bypass diodes.
Each terminal is dedicated to one
polarity (with the polarity symbols
engraved onto the body of the junc-
tion box) . See Figure 2-1.
A microinverter has an input / out-
put terminal. See Figure 2-2.
Each terminal is provided with facto-
ry installed lead cables and a latch-
ing connector. Always use these
connectors and do not detach them
from cables. See Figure 2-3.
The PV module and a microinverter
Negative ( - )
Positive ( + )
Figure 2-1. Junction Box
Cable
Connector
TM
MC
Plug
Option:
Safety lock clip
Negative ( - )
Figure 2-3. Connectors
come pre-wired. Each module has
two #12 AWG type PV-wire stranded
sunlight resistant output cables each
terminated with connectors. The
positive (+) terminal has a male
connector while the negative (-)
terminal has a female connector.
When making field wiring connec-
tions to the pre-attached connect-
ors, use only approved connectors
from Table.2.
Latching connectors are type IV and
supplied by STAUBLI ELECTRICAL
CONNECTORS AG, which are listed
by UL.
In order to comply with NEC 2008, a
locking sleeve needs to be used with
all connectors that are exposed.
The locking sleeve (PV-SSH4) is
made by STAUBLI and can only be
Side view
Output terminal
Figure 2-2. Output / input terminal of a Microinverter
Manufacturer
Contact Information
PV-KST4, PV-KBT4 followed by /2.5 or /6, followed by "I" or "II", followed by
-UR. or - may be followed by additional suffixes, may be followed by suffix
numbers and letters.
PV-PLS-S, PV-PLS-B, may be followed by suffix numbers and letters, may be
followed by suffix numbers and letters.
Male PV connectors,
PV-KST4-EVO2/2.5, 6 or 10, followed by I, II, III or IV, followed by -UR.
Positive ( + )
Female PV connectors,
PV-KBT4-EVO2/2.5, 6 or 10, followed by I, II, III or IV, followed by –UR
Top view
Input terminal
Table.2 Approved connectors list
STAUBLI ELECTRICAL CONNECTORS AG
http://ec.staubli.com
6
released with a special tool also
made by STAUBLI (PV-MS). Locking
sleeves are not supplied with mod-
ules and must be purchased sepa-
rately.
Enlarged view of
output terminals
Enlarged view of
input terminals