2. WIRING
How to fabricate cables connected to the FRP_TB board
(03P9548)
Signal cable RW-0013
(Fold back outer shield over the vinyl sheath.)
Vinyl sheath
Vinyl tape
Set this part in the cable clamp.
TTYCSLA cables
Armor
Secure tape with
cable tie (supplied).
Connector No.
J612 (NMEA1)
J613 (NMEA2)
J614 (NMEA3)
J615 (NMEA4)
J616 (NMEA5)
J617 (NMEA6)
J619 (ROT/RUDDER)
2-8
100
240
Wind the inner shield around the outer shield.
Coaxial cable
L2
Drain wire
Sheath
Vinyl tape
Set this part in cable clamp.
Pass the vinyl tape (local suppy) onto the drain wire. Attach a
crimp-on lug (preattached to the processor unit) to the drain wire.
Fasten the crimp-on lug to its original location.
Cable lengths of L1, L2 and L3 (mm)
Cable type
TTYCSLA-1T
TTYCSLA-4
TTYCSLA-1
TTYCSLA-1
TTYCSLA-4
TTYCSLA-4
TTYCSLA-7
Pull out wires from the inner shield.
Inner shield
8
Connect to WAGO connector.
15 515
Fold back shield.
L3
L1
L1 to 3: See the table shown on next page.
Crimp-on lug
L1
120
200
120
60
250
230
200
Conductor
8
5
L2
L3
60
80
60
150
60
100
100
120
80
200
80
200
60
120

Advertisement