TAN/TAG-A53EWI
INDICATION LAMP
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
※In this table TAN means indoor unit and TAG means outdoor unit.
CHECK A FOLLOWING STEPS
〔fig. 1〕Resistance of sensor
(temp. power module)
upward
PCB(AE main)
Take off the connector,
and measure the resistance between 3 and
4 in the connector.
〔fig. 3〕Voltage of TAN fan motor on the PCB(TAN main)
BL
Y
W
B
R
TAN fan motor connector
PCB(TAG main)
between red + and black − approx.DC325V
between yellow + and black − approx.DC3
between white + and black − approx.DC15V
〔fig. 5〕Resistance of 2-way valve coil
Normal:5.8kΩ
5.8kΩ
2-way valve coil
Take off the joint connector of 2-way
valve(TAN), and measure the
resistance of it.
All manuals and user guides at all-guides.com
not cool down
-
SENSOR, TEMP. HEAT EXCHANGER
not warm up
water leakage
-
in case of dry, not
-
dehumidify
-
nasty smell
louver doesn' t work
-
table 4
3
4
15
Measure the voltage between
the connector pins in the back
of PCB (TAN main) during
cooling operation.
PCB(TAN main)
5V
is Normal
〔fig. 6〕Resistance of louver motor
Take off the connector and check the
resistance between the teminals
TROUBLESHOOTING GUIDE
check the point of leakage measure the pressure of compressor
GAS LEAKAGE
during fixed operation (operation frequency 58 Hz)
SENSOR, TEMP. ROOM
check the resistance by tester [see table 1]
check the resistance by tester [see table 2]
4-WAY VALVE
check the resistance by tester [see fig.4]
SHORT CYCLE
check the blockage of air inlet & outlet of TAN, TAG
(INSUFFICIENT AIR CIRCULATION)
check the drain hose by eyes (it might be folded or choked)
DRAINAGE
check the TAN whether lean or not
MIS-INSTALLATION
check the resistance of coil (2-way valve) by tester
2-WAY VALVE(TAN)
(in case of dry operation) [see fig.5]
FILTER IS CHOKED
check by eyes and clean it
NO USE FOR A LONG TIME
NASTY SMELL
use deodorizer
(CIGARETTE, FURNITURE, ETC.)
LOUVER MOTOR
check the resistance by tester [see fig.6]
〔fig. 2〕Continuity of current fuse on the PCB (TAG main)
FUSE
Take off the connectors 1 & 5 on the PCB (TAG main), and
check the continuity.
〔fig. 4〕Resistance of 4-way valve coil
※ Take off the connector and check the Resistance
of 4-way valve coil
〔fig. 7〕Resistance of Power module
Normal:360 ∼ 390Ω
common terminal
360∼390Ω
Measure the resistance, six times between
U-V, V-W, W-U respectively by changing
the polarity,and if all the figures show
infinite (more than hundreds of k Ω ) then
it is normal condition.
– 23 –
FUSE
4-way valve coil
1.5kΩ
Normal:1.5kΩ
power module