AIRFLOW DIRECTION CONTROL
Horizontal Adjustment
Swing of Air Flow
The horizontal louver will keep moving steadly right and left if the horizontal louver button is pressed once.
Fixing the Flow Direction
The horizontal louver will come to a halt if the horizontal louver button is pressed once again.
NOTICE :
Dew drops may appear at the outlet under high humidity(e.g.during rainy season) if the system is operated
with the horizontal louver faced to the extreme right or left.
Use the wireless remote control unit without fail to change the angle of the horizontal louver. The horizontal
louver may move out of the normal range if forced by hands.
TIME DELAY SAFETY CONTROL FUNCTION - FOR PROTECTION OF COMPRESSOR
Compressor will not restart, in any operation modes, for 3 minutes after its stop.
Compressor does not stop during the first 6 minutes of its operation even if the room temperature reaches to
the designated temperature, except changing setting temperature.
COOLING MODE OPERATION
The compressor will stop when operational frequency reached the minimum frequency and that condition has
been kept for 6 minutes and the room temperature becomes 1℃ lower than it was set.
The compressor will re-start when room temperature becomes 0℃ higher than it was set.
The operational frequency will be set every ★1 seconds of operation.
The operational frequency setting will be calculated based on the deviation of the room temperature and the
set temperature on one end and the deviation factor at the time of previous setting on another.
Designated
temperature
0˚C
-1˚C
MAX
★2
Frequency of
compressor
0
Hz
All manuals and user guides at all-guides.com
TAN/TAG-A53EWI
MIN★3
TAN/TAG-A28EWI, TAN/TAG-A32EWI
TAN/TAG-A53EWI
– 11 –
OPERATION DETAILS
Room temperature
MIN★3
★1
★2
★3
40
90Hz
24Hz
120
100Hz
10Hz
MAX
★2