Fluke 113 Instruction Sheet page 15

Electrical multimeter
Table of Contents

Advertisement

Shop for Fluke products online at:
Model 113 English Instruction Sheet
Maximum Voltage
Between any Terminal
and Earth Ground:
600 V
Display:
3 3/4-digits, 6000 counts, updates 4/sec
Operating Temperature:
-10C to 50C (14F to 122F)
Storage Temperature:
-40C to 60C (-22F to 140F)
0.1 x (specified accuracy)/C (<18 C or
Temperature
>28 C)
Coefficient:
Operating Altitude:
2,000 m
Storage Altitude:
10,000 m
95 % to 30 C
Relative Humidity:
75 % to 40 C
45 % to 50 C
Battery Type:
9 Volt Alkaline, ANSI 1604A / IEC 6F22
Battery Life:
Alkaline: 300 hours typical, without
backlight
Shock:
1 Meter drop per IEC 61010-1-2001
Vibration:
Per MIL-PRF-28800 for Class 2
instrument
Size (H x W x L):
6.58 in X 3.35 in X 1.81 in (167.1 mm X
85.1 mm X 46.0 mm)
Weight:
13.0 oz (404 g)
Safety:
Complies with ANSI/ISA 82.02.01 (61010-
1) 2004, CAN/CSA-C22.2 No 61010-1-04,
UL 61010-1 (2004) and IEC/EN 61010-1
nd
2
Edition for measurement Category IV,
600 V, Pollution Degree 2, EMC
EN61326-1. S/N >17610000
EMI Regulations:
Complies with FCC Part 15, Class B
 
Certifications:
TUV, (