6. ZCZC Check
This is the setting whether or not to receive a message when there is an error between
ZCZC and the space after it. Always select "On".
- Off: When the error is not more than one character, the message is received.
- On: If there is an error, the message is not received.
Phasing signal
>> 10s
This section is checked.
7. 00 Msg Priority
This is the setting whether or not to receive a message when a message of "00" is
received from a following station.
1) Station set as "Not Receive" in [MENU] -> NAVTEX -> Rcv Station & Msg.
2) Station set as "Not Receive" from the INS, or
3) Station not selected in Auto mode.
- B1>00>B2: Not receive "00" message (for Russia Type approval)
- 00>B1>B2: Receive "00" message (For IEC standard)
Related setting:
- Program Ver-02.01
[MENU] -> NAVTEX -> Mask Mode
[MENU] -> NAVTEX -> Auto Rcv Mask
[MENU] -> NAVTEX -> Local Channel
[MENU] -> NAVTEX -> Rcv Mask
- Program Ver-01.02
[MENU] -> NAVTEX -> Receiver Mode
[MENU] -> NAVTEX -> Local Channel
[MENU] -> NAVTEX -> Rcv Station
8. Print Order
This is the setting of the printing order of messages when a received message list is
displayed and [PRINT] -> Print is executed.
- Old -> New: Printing is performed in the order starting from the oldest received
message.
- New -> Old: Printing is performed in the order starting from the newest received
message.
Related setting:
[MENU] -> System -> Printer
One
ZCZC
B1B2B3B4
space
2-26
2.6 Setting of Initialize-1 menu
CR
Message
NNNN
+ LF
(B1>00>B2/00>B1>B2)
(Old->New/New->Old)
(On/Off)