Discharge Pipe and Pressure Tank Connections / Electrical 6
STANDARD TANK CONNECTION
(FIGURE 6)
1. Install a tee in the pump discharge port (see Figure 6).
2. Run a pipe from the pump discharge port to the inlet
port of your tank. The pipe size must be at least as
large as the discharge port.
3. Install a tee with reducing bushings in the suction
pipe as shown in Figure 6.
4. Install a barbed fitting in the smallest bushing (1/8"
NPT).
5. Run the AVC tubing from the barbed fitting on the
suction pipe tee to the port in the AVC mounted on the
tank. See the instructions provided with the tank and
the AVC for details. The AVC port location may vary.
Congratulations! You have just completed the tank
connection for your jet pump.
To Household
Water System
Pump
Discharge
Port
AVC
Tube
1/8" NPT
Barbed
Install a tee in the suction line. Install
Fitting
reducing bushings down to 1/8" NPT
for the barbed fitting. Install the AVC
tube between the barbed fitting and
the port on the bottom of the AVC
(which is mounted on the tank).
Reducers
Figure 6 – Standard Tank Connections
WIRING CHART – RECOMMENDED WIRE AND FUSE SIZES
Maximum
Model
Volts
2800, 2800E
115
2802
115
2802E
115
2803
115
* When using fuses, dual element or Fusetron time delay fuses are recommended for all motor circuits.
For parts or assistance, call Simer Customer Service at
Air Volume
Control (AVC)
AVC Tubing
Suction Hose
From Well
Branch
Load
Circuit Breaker
Amps
Rating (Amps)*
7.2
15
8.6
15
8.6
15
10.5
15
ELECTRICAL
Hazardous voltage. Can shock, burn, or kill.
Connect ground wire before connecting power supply
wires. Use the wire size (including the ground wire) spec-
ified in the wiring chart. If possible, connect the pump to
a separate branch circuit with no other appliances on it.
Explosion hazard. Do not ground to a gas
supply line.
Wiring
Fire hazard. Incorrect voltage can cause a
fire or seriously damage the motor and voids the warranty.
The supply voltage must be within ±10% of the motor
nameplate voltage. Do not alter the wiring in the motor.
Connect to 115 Volt supply only.
Install, ground, wire, and maintain your pump in compli-
ance with the National Electrical Code (NEC) or the
Canadian Electrical Code (CEC), as applicable, and with
all local codes and ordinances that apply. Consult your
local building inspector for code information.
Connection Procedure:
Your Pressure Switch looks like one of those shown in
Figure 7. Connect the power supply as shown for your
type of switch.
1. Connect the ground wire first as shown in Figure 7.
The ground wire must be a solid copper wire at least
Tank
Inlet
as large as the power supply wires.
Port
2. There must be a solid metal connection between the
pressure switch and the motor for motor grounding
protection. If the pressure switch is not connected to
the motor, connect the green ground screw in the
switch to the green ground screw under the motor
end cover. Use a solid copper wire at least as large as
the power supply wires.
3. Connect the ground wire to a grounded lead in a ser-
vice panel, to a metal underground water pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground electrode provided by the power company or
the hydro authority.
Distance in Feet (m) from Motor To Supply
Wires Sizes AWG (mm
0-100 (0-30)
101-200 (31-61) 201-300 (62-91) 301-400 (92-122)
14 (2)
12 (3)
14 (2)
10 (5.5)
14 (2)
10 (5.5)
14 (2)
10 (5.5)
1-800-468-7867 / 1-800-546-7867
)
2
10 (5.5)
8 (8.4)
8 (8.4)
6 (14)
8 (8.4)
6 (14)
10 (5.5)
6 (14)