Daikin 3MKS75KVM Service Manual page 6

Removal procedure, 6.8/7.5 kw class, 18000 btu/h class, outdoor unit, inverter, multi type, cooling only, heat pump
Hide thumbs Also See for 3MKS75KVM:
Table of Contents

Advertisement

Removal of Electrical Box (Pattern 1)
Step
2. Remove the harnesses.
Disconnect the
1
connectors for the
electronic expansion
valve coils. [S20] [S21]
[S22].
Remove the connector
2
for the four way valve
coil [S80].
Disconnect the
3
connectors for the
thermistors [S90] [S92]
[S93] and the connector
for the overload
protector [S40].
4
Disconnect the relay
connector of the
compressor.
4
Procedure
[S20] [S21] [S22]
[S80]
[S90] [S92] [S93]
[S40]
Points
(R16025)
(R11729)
[S40]: Overload protector
[S90]: Thermistor
(outdoor temperature,
outdoor heat exchanger,
discharge pipe)
[S92]: Gas pipe thermistor
[S93]: Liquid pipe thermistor
(R2168)
(R2169)
Removal Procedure
Si121175

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3mks75evma2mxs18gvju3mxs68evma3mxs68kvm

Table of Contents