Si121175
Step
5
Peel off the putty and
pull out the thermistors.
Remove the wire
6
harness.
Removal Procedure
Procedure
Gas pipe thermistor
Removal of Coils / Thermistors
Place the thermistor so that
its end comes up to the end
of the fixture.
Liquid pipe
Be careful not to lose the clip
thermistor
or fixtures for the liquid and
gas pipe thermistor.
(R2198)
[S90]:
Outdoor temperature thermistor
(Blue)
Heat exchanger thermistor
(Gray)
Discharge pipe thermistor
(Black)
[S92]: Gas pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Brown)
[S93]: Liquid pipe thermistor
Room A (Black)
Room B (Gray)
Room C (Yellow)
(R2199)