Disabling The High Voltage System; Front Trunk First Responder Cut Loop - Tesla 3 Emergency Response Manual

Hide thumbs Also See for 3:
Table of Contents

Advertisement

FRONT TRUNK FIRST RESPONDER CUT LOOP

FRONT TRUNK FIRST RESPONDER CUT LOOP
The first responder loop is a low voltage harness. Cutting the first responder loop shuts down the high voltage system outside of the
high voltage battery and disables the SRS and airbag components. Refer to
for instructions on how to access and cut the first responder loop.
NOTE: The following image shows a Dual Motor vehicle. Vehicles without a front drive unit are similar.
Warning: Regardless of the disabling procedure you use, ALWAYS ASSUME THAT ALL HIGH VOLTAGE COMPONENTS ARE
ENERGIZED! Cutting, crushing, or touching high voltage components can result in serious injury or death.
12
Cutting the Front Trunk First Responder Loop
on page 13

Advertisement

Table of Contents
loading

Table of Contents