The use of the steam dispensing point (auto-
!
steamer nozzle), must always be preceded by
the performance of the condensation draining
operation for at least 2 seconds.
i
The system includes a time limit of a maximum
of 4 minutes for autosteamer operation.
i
To change the temperature of the autosteamer,
and to enable or disable its operation, contact
the Technical Support Service.
To keep the steam dispensers in perfect work-
ing order, it is advisable to carry out a brief
!
delivery dry run after each use. Keep the tips of
the autosteamer clean at all times using a cloth
dampened in lukewarm water. If regular clean-
ing is not carried out, the proper operation of
the autosteamer can be compromised.
Do not leave the autosteamer nozzle immerged
!
in the milk when it is not being used. Handle
the autosteamer with utmost caution due
to the hazard resulting from the presence of
high-temperature steam.
18
12

Energy Saving System

The machine is provided with a software that
manages the automatic standby sistem during
breaks, the night Energy-saving feature and the
intelligent adjustment of the temperature.
This allows a considerable energy saving, during
night breaks, maintaining the machine in the condi-
tion to quickly return to operate.
Moreover, the software distributes the power
only where and when it is needed, thus allowing
to save energy during the normal working activity
too.
If provided for in the programming, it automati-
cally puts into standby one or more groups when
the workload decreases and prepares them for full
capacity when needed.
All this is indicated in the following way:
ENERGY SAVING
+ fl ashing of the
"PROG/STOP" LEDs
Flashing "PROG/STOP"
LED
To bring a dispensing group back from standby,
press and hold the respective "PROG/STOP" button
for 3 seconds.
It will return to full operation in about 1-2 min-
utes.
If the machine is in the "ENERGY SAVING" mode,
also the services boiler will be reactivated, thus exit-
ing the "energy saving" mode.
The dispensing groups and the services boiler,
which have been reactivated, will remain opera-
tive until the next time limit set for the start-up of
the energy saving mode (for the machine) or of the
standby mode (for the dispensing groups) expires.
The system will continue to follow the pro-
grammed energy saving settings.
i
To change the operating parameters of the
"energy saving" system, contact the Technical
Support Service.
All the groups are in
standby, the entire ma-
chine (including the serv-
ices boiler) is in energy
saving phase.
One or more delivery
groups (but not all of them)
are in standby.
User manual