Before lighting the stove, ensure that any build-up in the firebox has been removed and that the ashpan has
been emptied.
2.
Open the spin valve by turning it anti-clockwise until fully open (see Figure 1).
3.
Lay a few crumpled sheets of paper on the grate a few small sticks, kindling or an approved firelighter add a
small quantity of fuel. Light the fire and close the firebox door.
4.
Never use inflammable liquid i.e. gasoline, petrol paraffin etc. to start or freshen up" a fire in this heater.
5.
When the fire is well established add fuel to the firebox and adjust the spin valve to the required setting.
Riddle the fire by connecting the grate operating tool onto the rocker connection located at the bottom front of the
stove, then gently pull and push the rocker arm until all dead ash has fallen through into the ashpan (See Figure 2).
Before opening the door, open the spin valve by turning it anti-clockwise, as this will help to eliminate any smoke or
fly ash resident in the combustion chamber. Add fuel to fire, close fire door and re-set spin valve to required setting.
Slow burning will cause the window glass to blacken and should not be used for a long period. Opening the air con-
trols will increase the heat output and should remove most of the soot deposits from the glass. For low burning set-
ting open the spin valve so that it is between 0.5- 1 mm open. This opening size should be taken as a guideline and
may need to be increased/decreased depending on the draught generated by the chimney to which the stove is con-
nected.
NOTE:
THESE INSTRUCTIONS ARE NOT INTENDED TO SUPERSEDE/REPLACE THE USER MANUAL
ACCOMPANYING THE STOVE AND ARE FOR GUIDE PURPOSES ONLY.
U S E R I N S T R U C T I O N S
LIGHTING THE STOVE
LIGHTING THE STOVE
LIGHTING THE STOVE
LIGHTING THE STOVE
Figure 1
Figure 2
REFUELLING
REFUELLING
REFUELLING
REFUELLING
SLOW BURNING
SLOW BURNING
SLOW BURNING
SLOW BURNING
OISIN SF STOVE

Advertisement

loading

Summary of Contents for Stanley OISIN SF

  • Page 1 OISIN SF STOVE U S E R I N S T R U C T I O N S LIGHTING THE STOVE LIGHTING THE STOVE LIGHTING THE STOVE LIGHTING THE STOVE Before lighting the stove, ensure that any build-up in the firebox has been removed and that the ashpan has been emptied.
  • Page 2 OISIN SF STOVE M A I N T E N A N C E I N S T R U C T I O N S MONTHLY MAINTENANCE MONTHLY MAINTENANCE MONTHLY MAINTENANCE MONTHLY MAINTENANCE Cleaning Stove Flue Pathways To access the flue pathways, the top baffle should be removed from the stove through the fire door opening and cleaned thoroughly.

This manual is also suitable for:

Oscar sf