TABLE 5: Status Code Display & Timing
Duration of
connection (seconds)
< 2
2-6
> 6
Pushbutton signal removed
Pushbutton signal not removed
1. If the PUSH BUTTON is pressed during two-stage anticipation mode, with an active thermostat call. The control will remove the forced second stage.
TABLE 6: Fault Code
Description
Control Fault
Control Failure
Operational Faults
High-pressure switch fault (not in lockout yet) HPS Opening
System in high-pressure switch lockout
System in high-pressure switch lockout
Low-pressure switch lockout
Low-pressure switch lockout
Cooling LTCO Active
Low Voltage (<19.2VAC) preventing further
relay outputs for > 2 seconds
Low Voltage (<16 VAC) stopped
current relay outputs for > 2 seconds
Required Sensor or Switch Faults
Outdoor ambient sensor failure (short)
Outdoor ambient sensor failure (open)
Discharge line sensor failure (short)
Continued on next page.
20
Control behavior with no thermostat signals present Control behavior with thermostat signals present
Display Operational Mode (AC or HP) (5 sec)
Display Current/Stored Fault Code(s) if present
Note: If a fault condition is active, the control will
continue to display the active fault. It will not display
stored faults until the active fault is cleared.
Clear soft lockout
Clear hard lockout
Set Tonnage Configuration (5 sec), ONLY if the
Tonnage Configuration Error fault is currently active.
Set Operational Mode (AC or HP) (5 sec), ONLY if
the AC/HP Mode fault is currently active.
Note: If either of the previous 2 actions were taken, the
following will not occur on the same PUSH BUTTON
press. 
Clear Fault Code Array, if faults are present
Clear soft lockout
Clear hard lockout
Resume normal LED display
Display will toggle between Operational Mode (AC/HP)
(5 sec) and Tonnage Configuration (5 sec)
Required Condition
Control Failure Detected
HPS Openings
2 HPS faults within 6 hours
HPS Openings
4 HPS soft lockouts within 12 hours
or a combination of 4 soft lockouts
LPS open > 5 seconds
1 fault occurrence
LPS open > 5 seconds
4 LPS soft lockouts within 12 hours
or a combination of 4 soft lockouts
Call for cooling below 35°F
Further calls for relay outputs
prevented based on low voltage
Relay outputs stopped
based on low voltage
Control senses a shorted sensor
Control senses an open sensor
Control senses a shorted sensor
1 fault occurrence
Display PWM sent to the ODF (5 sec)
Bypass ASCD (Reduce timer to zero immediately).
If Y1 is present and high-pressure switch is closed,
contactors will be energized.
Clear soft lockout; Except Fault Codes 25, 26, and 30.
Clear hard lockout; Except Fault Codes 25, 26, and 30.
Will not initiate a defrost cycle in an A/C application.
Clear soft lockout; Except Fault Codes 25, 26, and 30.
Clear hard lockout; Except Fault Codes 25, 26, and 30.
Resume normal LED display
Resume normal LED display
7-Segment
7-Segment
LED
Display 1
Display 2
RED
0
0
(solid)
RED
0
1
(solid)
2 RED
0
2
flashes
3 RED
0
2
flashes
2 RED
0
4
flashes
3 RED
0
4
flashes
RED
0
5
(solid)
RED
0
6
(solid)
RED
0
7
(solid)
RED
0
9
(solid)
RED
1
0
(solid)
2 RED
1
3
flashes
Johnson Controls Unitary Products
1
Control
Response
Failure
Fault, None Lockout
Soft Lockout
Hard Lockout
Soft Lockout
Hard Lockout
Fault, None Lockout
Fault, None Lockout
Fault, None Lockout
Fault None Lockout;
ODF will operate at
units Max PWM.
Fault None Lockout;
ODF will operate at
units Max PWM.
Soft Lockout