7DEOH
7URXEOHVKRRWLQJ 7DEOH FRQWªG
Problem
HW Event
Description
Category
Temperature
Critical
is under limit
Major
Warning
Voltage is over
Critical
limit
Major
Warning
Voltage is
Critical
under limit
Major
Warning
Peer BCC
Major
status,
Warning
temperature
and voltage
are Not
Available
All manuals and user guides at all-guides.com
LED
STM
State
Status
none
Critical
Temps
<9.5º C
none
Non-
critical
Temps
<15.5º C
none
Critical
none
Non-
critical
none
Critical
none
Non-
critical
none
Both
BCCs:
Non-
critical
none
Not
Available
Probable Cause/Solution
– Room temperature is too low.
– Temperature sensor is faulty. Compare
temperature reported by peer BCC.
Power supply is faulty. Check status and
correct.
Either power supply is faulty. Check status
and correct.
Firmware on BCC A and BCC B are
different versions.
Internal bus is faulty. Contact HP technical
support to replace backplane.
,VRODWLQJ )DXOWV
101