HP SuperStore E SC10 User's And Service Manual page 100

Disk system
Table of Contents

Advertisement

7DEOH 
7URXEOHVKRRWLQJ 7DEOH FRQWªG
Problem
HW Event
Description
Category
Power supply
Critical
LED is amber
IOSCAN lists
Critical
BCC and
disks as
NO_HW
IOSCAN lists
none
disk as
NO_HW
Temperature
Critical
is over limit
Major
Warning
7HPSHUDWXUH VHQVRUV DUH RQ WKH
%&& DQG DUH LQGHSHQGHQW RI SRZHU
VXSSOLHV ,QYHVWLJDWH WHPSHUDWXUH
ZDUQLQJV LPPHGLDWHO\ EHIRUH
SRZHU VXSSOLHV VHQVH FULWLFDO
WHPSHUDWXUH DQG WXUQ RII
,VRODWLQJ )DXOWV
100
All manuals and user guides at all-guides.com
LED
STM
State
Status
Amber
Critical
All normal
none
All off
none
On or off
(See STM
Disk Tool)
none
Critical
Temp is
>54.5º C
none
Non-
critical
Temp is
>36º C
Probable Cause/Solution
– An incompatible or defective component
caused a temporary fault.
– Power supply hardware is faulty.
Unplug the power cord and wait for the LED
to turn off. Reinsert the power cord. If fault
persists, replace the power supply.
– SCSI cable is unplugged or loose at
either end.
– SCSI cable is damaged. Replace with
another cable to test.
– Prior unit in the daisy chain is powered
off.
– HBA is faulty. Check status and correct
any problem.
Disk system is powered off.
– Disk is faulty. Replace.
– Backplane is faulty. Replace.
– A fan is faulty. Check status and correct.
– Airflow is obstructed; vents are blocked.
– One or more slots are empty.
– Power supply is faulty. Check status and
correct.
– Room temperature is too high. If ambient
temperature cannot be reduced in a
reasonable time, turn off product to
prevent shortened life.
– Temperature sensor is faulty. Compare
temperature reported by peer BCC.