Cleveland Steamcraft II Service Manual page 26

Table of Contents

Advertisement

COMPLAINT 5. GENERATOR WILL NOT FILL WITH WATER WHEN POWER SWITCH IS ON
POSSIBLE CAUSES
I.
If power light is off :
A.
Power switch
B.
Power supply
C.
Control fuse
II.
If power light is on and no voltage is measured across the fill solenoid coil :
A.
If no voltage is measured across
1.
B.
If 120 volts is measured across LI & L2 on the level control board and no
voltage is measured from L2 to WF on the level board :
1.
2.
C.
If 120 volts is measured across LI & L2 on the level control board and 120
volts is measured from L2 to WF on the level board.
1.
Broken wire connection from WF to water fill solenoid or from solenoid
coil to transformer.
III. If power light is on and 120 volts is measured across the fill solenoid coil.
A.
Water supply off.
B.
Fill solenoid clogged with scale.
C.
Fill solenoid mechanically stuck.
D.
Fill solenoid coil open.
TROUBLESHOOTING CHART
Broken wire connection from power switch to level board.
Faulty level control board.
Check for grounded probe.
LI & L2 on the level control board :