Lenovo ThinkServer sd350 Installation And Service Manual page 181

Machine type: type 5493 and 5495
Hide thumbs Also See for ThinkServer sd350:
Table of Contents

Advertisement

0C0301D2 Mem_Therm_Trip
196F01D3 PCH_Therm_Trip
0D6F01D4 HDD_Status
1D6F02E0 BIOS_Boot_up
0C6F00E2
Memory_Status
0C6F01E2
Memory
temperature is too
Sensor Type: Memory
high. At the same
Event Severity: Critical
time, system will be
Description: State
shutdown.
Asserted - Asserted
PCH temperature
is too high. At the
Sensor Type: Chipset
same time, system
Event Severity: Critical
will be shutdown.
Description: State
Asserted - Asserted
Sensor Type: Drive Slot
HDD % fault. (% =
(Bay) Event Severity:
HDD number)
Critical Description: Drive
% Fault - Asserted
Sensor Type: System
Boot / Restart Initiated
BIOS boot up and
Event Severity: Info
it's initiated by
Description: Initiated By
warm reset.
Warm Reset - Asserted
A single bit error
Sensor Type: Memory
is occurred In
Event Severity: Critical
memory. This error
Description: Correctable
will be repaired
ECC - Asserted
automatically.
Sensor Type: Memory
A multiple bits
Event Severity:
error is occurred in
Critical Description:
memory. This error
Uncorrectable ECC -
will cause system
Asserted
to be hang up.
1. Check the Lenovo support website for an
applicable tip or firmware update that applies
to this error. 2. Check Fan status. if Fan
is broken, please replace the new Fan. 3.
Contact your Lenovo service representative
for support
1. Check contact condition of PCH heat
sink. 2. Check the Lenovo support website
for an applicable tip or firmware update that
applies to this error. 3. Check Fan status. if
Fan is broken, please replace the new Fan. 4.
Contact your Lenovo service representative
for support
1. Check Lenovo support site for an
applicable service bulletin or firmware update
that applies to this error. 2. Replace HDD. 3.
Contact your Lenovo service representative
for support.
It is just an information. Users don't need to
do anything.
1. If the node has recently been installed,
moved, serviced, or upgraded, verify that the
DIMM is properly seated and visually verify
that there is no foreign material in any DIMM
connector on that memory channel. If either
of these conditions is found, correct and retry
with the same DIMM 2. If problem re-occurs
on the same DIMM connector, swap the
other DIMMs on the same memory channel
across channels one at a time to a different
memory channel or Processor. (check service
information for this product/Install guide for
population requirements for sparing/paring
modes). If problem follows a moved DIMM
to a different memory channel, replace that
DIMM.
1. Check the Lenovo support website for
an applicable service bulletin or firmware
update that applies to this memory error.
2. If the node has recently been installed,
moved, serviced, or upgraded, verify that the
DIMM is properly seated and visually verify
that there is no foreign material in any DIMM
connector on that memory channel. If either
of these conditions is found, correct and
retry with the same DIMM. 3. If no problem
is observed on the DIMM connectors and
the problem persists, replace the DIMM
identified by LightPath and/or event log
entry. 4. If problem re-occurs on the same
DIMM connector, swap the other DIMMs on
the same memory channel across channels
one at a time to a different memory channel
or Processor. (check service information
for this product/Install guide for population
Appendix A. TMM error messages
165