Lenovo ThinkServer sd350 Installation And Service Manual page 180

Machine type: type 5493 and 5495
Hide thumbs Also See for ThinkServer sd350:
Table of Contents

Advertisement

236F00C4
236F01C4
IPMI_Watchdog
236F02C4
236F03C4
076F01C5
CPU%_Status (% =
076F01C6
CPU number)
070301C7
PROC_Hot
076F0AC7
CF6F00C9 Chassis_Control
070301D0 CPU_CATERR
070301D1 CPU_VR_Fault
164
Lenovo ThinkServer sd350 Server Type 5493, Lenovo ThinkServer n400 Enclosure Type 5495Installation and Service Guide
Sensor Type: Watchdog
2 Event Severity: Info
Description: Time Expired
- Asserted
Sensor Type: Watchdog
2 Event Severity: Info
Description: Hard Reset -
Asserted
Sensor Type: Watchdog
2 Event Severity: Info
Description: Power Down
- Asserted
Sensor Type: Watchdog
2 Event Severity: Info
Description: Power Cycle
- Asserted
Sensor Type: Processor
Event Severity: Critical
Description: Thermal Trip
- Asserted
Sensor Type: Processor
Event Severity: Warning
Description: State
Asserted - Asserted
Sensor Type: Processor
Event Severity: Warning
Description: Processor
Automatically Throttled -
Asserted
Sensor Type: Customer
Sensor Type Event
Severity: Info Description:
Chassis Control -
Asserted
Sensor Type: Processor
Event Severity: Critical
Description: State
Asserted - Asserted
Sensor Type: Processor
Event Severity: Critical
Description: State
Asserted - Asserted
The watchdog timer
It is just an information. Users don't need to
is expired.
do anything.
The Hard Reset
It is just an information. Users don't need to
is triggered by
do anything.
watchdog.
The Power Down
It is just an information. Users don't need to
is triggerred by
do anything.
watchdog.
The Power Cycle
It is just an information. Users don't need to
is triggered by
do anything.
watchdog.
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
CPU temperature
for an applicable tip or firmware update that
is too high. At the
applies to this error. 3. Check Fan status. if
same time, system
Fan is broken, please replace the new Fan. 4.
will be shutdown.
Contact your Lenovo service representative
for support
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
CPU begins to
for an applicable tip or firmware update that
throttle because its
applies to this error. 3. Check Fan status. if
temperature is too
Fan is broken, please replace the new Fan. 4.
high.
Contact your Lenovo service representative
for support
1. Check contact condition of CPU heat
sink. 2. Check the Lenovo support website
CPU begins to
for an applicable tip or firmware update that
throttle which is
applies to this error. 3. Check Fan status. if
triggered by PSU
Fan is broken, please replace the new Fan. 4.
alert.
Contact your Lenovo service representative
for support
BMC gets "Chassis
It is just an information. Users don't need to
Control" command.
do anything.
1. Check the Lenovo support website for
an applicable tip or firmware update that
Catastrophic error
applies to this error. 2. Restart the server. 3.
happened.
Contact your Lenovo service representative
for support
1. Check the Lenovo support website for
an applicable tip or firmware update that
CPU VR fault.
applies to this error. 2. Restart the server. 3.
Contact your Lenovo service representative
for support