  • Page 1 MAKING MODERN LIVING POSSIBLE Installation Guide ® CANopen MCA 105 ® AutomationDrive FC 301/302 vlt-drives.danfoss.com...
  • Page 3: Table Of Contents

    3.7 Electrical Installation 3.8 Reassembling Cover 3.9 Applying Power 3.10 Checking Network Cabling 4 Troubleshooting 4.1 Warnings and Alarms 4.2 Troubleshooting 4.2.1 LED Status 4.2.2 No Communication with the Frequency Converter Index MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 4: Introduction

    Supplementary publications and manuals are available from Danfoss. See vlt-drives.danfoss.com/Support/Technical- Documentation/ for listings. More approvals and certifications are available. For more information, contact a Danfoss local partner. Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 5: Disposal

    Remote transmission request frame Receive data Status word Service data object SYNC Object for synchronisation of process data TPDO Transmit process data object Transmit data Table 1.1 Symbols and Abbreviations MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 6: Safety

    Leakage currents exceed 3.5 mA. Failure to ground the frequency converter properly can result in death or serious injury. • Ensure the correct grounding of the equipment by a certified electrical installer. Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 7 An internal failure in the frequency converter can result in serious injury, when the frequency converter is not properly closed. • Ensure that all safety covers are in place and securely fastened before applying power. MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 8: Installation

    • Use high-strand wire to reduce electrical interference. ≥ 200mm Fieldbus cable 90° crossing Illustration 3.1 Cable Routing Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 9: Mounting

    Mount the new LCP cradle. Illustration 3.3 Top Cable Entry: Option Mounted with Connector Facing Up LCP cradle Fieldbus option Connector Illustration 3.2 Exploded View Illustration 3.4 Bottom Cable Entry: Option Mounted with Connector Facing Down MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 10: Setting Address Switches

    Illustration 3.5 Wiring for Enclosure Sizes A1–A3 Baudrate Maximum Resistance Cable cross- Termination [kbps] cable [mΩ/m] section resistor [Ω] length [m] <60 0.34–0.6 <40 0.5–0.6 1000 2500 <26 0.75–0.8 5000 Table 3.3 Cable Specifications Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 11 4 (CAN_H). The resistors have the following specification: • 121 Ω • 1% Metal film • 1/4 W Illustration 3.8 Wiring for Enclosure Sizes A4–A5, B1–B4, and C1–C4 Illustration 3.7 Termination Resistor Mounted MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 12: Reassembling Cover

    10-02 MAC ID to set the address. Connect to a running CANopen master. Check that network cabling is correct or not. Illustration 3.9 Wiring for Enclosure Sizes D, E, and F Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 13: Troubleshooting

    Counter. These 2 parameters have to be close to 0 ® Illustration 4.1 LED Panel VLT CANopen MCA 105 most of the time. If they show higher values, check the CANopen cable for interference, wrong termination, and so on. MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 14: Index

    EMC-compliant installation..............6 Exploded view..................7 Grounding....................6 High voltage..................... 4 Intended use..................... 2 Items supplied..................2 Leakage current..................4 LED panel....................11 LED status....................11 Load sharing..................... 4 Motor wiring..................... 6 Mounting....................7 Danfoss A/S © 05/2015 All rights reserved. MG33J402...
  • Page 15 Index Installation Guide MG33J402 Danfoss A/S © 05/2015 All rights reserved.
  • Page 16 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.