VERTICAL MOUNT AIR HANDLERS
INSTALLATION INSTRUCTIONS
Important Safety Instructions
As a professional installer, you have an obligation to know the
product better than the customer. This includes all safety pre-
cautions and related items. Prior to actual installation, thor-
oughly familiarize yourself with this Instruction Manual. Pay
special attention to all safety warnings. Remember, it is your
responsibility to install the product safely and to know it well
enough to be able to instruct a customer in its safe use.
Safety is a matter of common sense...a matter of thinking be-
fore acting. Most dealers have a list of specific, good safety
practices...follow them.
The precautions listed in this Installation Manual are intended
as supplemental to existing practices. However, if there is a
direct conflict between existing practices and the content of
this manual, the precautions listed here take precedence.
HIGH VOLTAGE!
Disconnect ALL power before servicing or
installing this unit. Multiple power sources
may be present.
Failure to do so may cause property
damage, personal injury or death.
CARBON MONOXIDE POISONING HAZARD
Special Warning for Installation of Furnace or Air Handling Units in
Enclosed Areas such as Garages, Utility Rooms or Parking Areas
Carbon monoxide producing devices (such as an automobile, space
heater, gas water heater, etc.) should not be operated in enclosed areas
such as unventilated garages, utility rooms or parking areas because of
the danger of carbon monoxide (CO) poisoning resulting from the exhaust
emissions. If a furnace or air handler is installed in an enclosed area such
as a garage, utility room or parking area and a carbon monoxide producing
device is operated therein, there must be adequate, direct outside
ventilation.
This ventilation is necessary to avoid the danger of CO poisoning which
can occur if a carbon monoxide producing device continues to operate in
the enclosed area. Carbon monoxide emissions can be (re)circulated
throughout the structure if the furnace or air handler is operating in any
mode.
CO can cause serious illness including permanent brain damage or death.
© 2005-2009 Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com -or- www.amana-hac.com
P/N: IO-281J
Installations and repair of this unit should be
performed
requirements of an "Entry Level Technician" as
specified by the Air Conditioning, Heating, and
Refrigeration Institute (AHRI). Attempting to install
or repair this unit without such background may
result in product damage, personal injury, or death.
This unit should not be connected to, or used in con-
junction with, any devices that are not design certified
for use with this unit or have not been tested and
approved by Goodman. Serious property damage or
personal injury, reduced unit performance and/or
hazardous conditions may result from the use of devices
that have not been approved or certified by Goodman.
To prevent the risk of property damage, personal injury,
or death, do not store combustible materials or use
gasoline or other flammable liquids or vapors in the
vicinity of this appliance.
Have your contractor identify all the various cutoff switches
and devices that service this unit. Know where the switch is
that will cut off energy to the heating system in the event of
overheating.

Shipping Inspection

Upon receiving the product, inspect it for damage from ship-
ment. Shipping damage, and subsequent investigation is the
responsibility of the carrier. Verify the model number, specifi-
cations, electrical characteristics, and accessories are cor-
rect prior to installation. The distributor or manufacturer will not
accept claims from dealers for transportation damage or in-
stallation of incorrectly shipped units.
Codes & Regulations
This product is designed and manufactured to comply with
national codes. Installation in accordance with such codes and/
or prevailing local codes/regulations is the responsibility of the
installer. The manufacturer assumes no responsibility for equip-
ment installed in violation of any codes or regulations.
B10259-216
-
Date: December 2009
ONLY
by individuals meeting the
WARNING
CAUTION

Advertisement

Table of Contents
loading

Summary of Contents for Goodman AWUF18

  • Page 1: Shipping Inspection

    Goodman. HIGH VOLTAGE! WARNING Disconnect ALL power before servicing or installing this unit.
  • Page 2 Phone: 704-334-5311 the installation and service of this product. Should you have any questions please contact the local office of the EPA. AWUF18-24 - Part #BT1369604,14” x 18” x 1” Replacement Parts AWUF36 - Part #BT1369606,16” x 20” x 1”...
  • Page 3: High Voltage

    Electrical Supply Wire and MOP Maximum Allowable Length in Feet to Limit Voltage Drop to 2%* Minimum Circuit Ampacity (MCA) Wire Size HIGH VOLTAGE (AWG) To avoid the risk of fire or equipment damage, use only copper conductors. Disconnect ALL power before servicing or installing this unit.
  • Page 4: Maintenance

    However, in mix-matched applications, a flowrator 12. After installation, evacuation and charging of the low side change may be required. See the Goodman piston kit chart or is complete, check fittings for leaks. consult your local distributor for details regarding mix-matched orifice sizing.
  • Page 5 SUCTION LINE LIQUID LINE REMOVABLE SERVICE DOOR FRONT ACCESS PANEL SMALL CHASSIS BOTTOM PRIMARY AND SECONDARY DRAINS CAN BE ACCESSED THROUGH THE BOTTOM OF THE UNIT. (3/4" NPT FEMALE CONNECTION) NOTE: HAND TIGHTEN ONLY CABINET DIMENSIONS LARGE CHASSIS SMALL CHASSIS 2.5 &...
  • Page 6: Wire Color

    NOTE: SPECIFICATIONS & PERFORMANCE DATA LISTED HEREIN ARE SUBJECT TO CHANGE WITHOUT NOTICE NOTE: Thermostat heat anticipator setting is 0.2. AWUF18, 24, 30, 36, 37 TAPE AWUF31/32 NOTE: Connect to the going to the outdoor unit. TAPE NOTE: Connect appropriate speed tap (Pink/Purple/Yellow) to T1.
  • Page 7 BLOWER CHART FOR VERTICAL MOUNT AIR HANDLERS CFM delivered against External Static Pressure Model Speed 0.1" 0.2" 0.3" 0.4" 0.5" High AWUF18XX1/16A* High AWUF18XX16B* High AWUF24XX1/16A* High AWUF24XX16B* High 1250 1195 1135 1085 1010 AWUF30XX1/16A* 1110 1055 1020 High 1255 1120 1100 1020...
  • Page 8 THIS PAGE LEFT INTENTIONALLY BLANK © 2005-2009 Goodman Manufacturing Company, L.P. 5151 San Felipe, Suite 500, Houston, TX 77056 www.goodmanmfg.com -or- www.amana-hac.com...

This manual is also suitable for:

Awuf30Awuf36Awuf24Awuf37Awuf31Awuf32

Table of Contents