Purging The Syrup Lines

The purge process is performed as part of the "Syrup Line Cleaning & Sanitizing" section on page 25. If a BIB con-
tainer is replaced, the syrup lines need to be purged and sanitized. To purge the lines, perform the procedure in Table
13.
Step
1
Ensure that the water and CO
Display the keypad screen by tapping each cor-
ner of the video screen starting in the upper right
corner (1) and continuing to tap each corner in a
counterclockwise direction, in a sequence of
1,2,3 and 4 as shown in Figure 36.
2
NOTE: As each corner is touched, a
small confirmation rectangle may
momentarily appear to confirm
the touch.
Input the proper password for your access level
3
(technician) and press Enter.
4
The Service UI screen is displayed.
5
Press the Unit Setup button.