To test the travel limits:
 Open the console door.
 Press and release the UP button and ensure that the door
moves to the programmed open position. The button will
blink as the door moves then shine continuously once the
door is in the open position.
 Press and release the DOWN button to ensure that the
door moves to the programmed down position. The button
will blink as the door moves then shine continuously once
the door is in the down position.
NOTE: After testing is complete, the light for both the UP
and DOWN buttons will turn off.
 If the travel limits were set incorrectly, they can be cleared
by pressing and holding the SET button for five seconds.
The UP and DOWN buttons will blink two times indicating
that the unit is ready to be reprogrammed.
 If you attempt to operate the garage door opener before
setting the travel limits or after setting the travel limits
incorrectly, a buzzer will sound once and the UP and
DOWN buttons will blink seven times.
 If the safety sensors become misaligned during testing, a
buzzer will sound twice and the UP and DOWN buttons
will blink eleven times.
NOTE: To align the sensors, refer to Aligning The Safety
Sensors earlier in this manual.