DISPLAY SETTINGS
Description/Action
Press Display Settings from the Main Menu to enter this menu. This
menu contains adjustable display options for viewing information on
the UIM's LCD screen. Use the Slidebar to navigate the menu.
Temperature Units - Adjustable user setting that changes
temperature units display to Celsius °C or Fahrenheit °F.
Backlight Delay - Adjustable user setting that determines
how long the UIM's LCD backlight remains illuminated after a
key has been pressed. Available settings are; Always Off, 10,
30 or 60 seconds and Always On.
Contrast - Adjustable user setting to adjust the UIM's LCD
screen contrast between text and background.
NOTE: These settings are adjusted in the same way described for
the
Operating Set Point and Differential Adjustment
HEATER INFORMATION
Description/Action
Press Heater Information from the Main Menu to enter this menu. This
menu contains non adjustable operational information.
Elapsed Time - Total accumulated time the control system
(water heater) has been energized.
Burner On Time - Total accumulated time the control system
has been in the heating operating state; burner run time.
Total Cycle Count - Total accumulated count of heating
cycles.
CCB Version - Software version for central control board.
Config CRC - Verifies the configuration key matches the
CCB programming.
UIM Version - Software version for user interface module.
Use External Enable - Enables/Disables the external enable
circuit.
External Enable Status - Displays whether or not the
external enable circuit has been activated.
Ignition Trials - Displays the number of ignition trials allowed.
NOTE: Historical data is stored in the configuration key. If
this "key" is replaced during servicing the historical data will
be lost. The data stored in the new configuration key will
no longer reflect the entire history of the water heater. The
configuration key should never be replaced unless directed
by Technical Support.
The Elapsed Time, Burner On Time, and Cycle Count indicate
age, usage, and wear.
If the Cycle Count per day is high (divide cycle count by
days to determine cycles per day) or the cycle duration is
short (determine burner on time total minutes, divide burner
on time total minutes by cycle count) consider rasing the
Differential setting to avoid short cycling and excessive
component wear, see
(page 44).
Adjustment
This historical data can also be used to assist facilities
managers in forecasting planned replacement of equipment
to help avoid lengthy and costly hot water supply interruptions.
(page 44).
Operating Set Point and Differential
Display Settings
Temperature Units
Brightness
Backlight Delay
Language
Heater Information
Elapsed Time 0days 0hrs 43mins >
Burner On Time 0days 0hrs 1mins
Use External Enable
External Enable Status
Ignition Trials
Total Cycles Counter
Bottom of Menu
Heater Information
Ignition Failure Count
Flame Loss Count
CCB Version
Config CRC
UIM Version
Configuration Raw
46
Display
°F >
5 >
30s >
English >
BACK
HELP
Display
No >
No >
3 tries >
2 >
BACK
HELP
1 >
0 >
3.17 >
0xD7A7 >
2.58 >
0x510C >
BACK
HELP

Advertisement

Table of Contents
loading

This manual is also suitable for:

301 series

Table of Contents