SiEBE04-507

4. Troubleshooting

4.1

Error Codes and Description

System
Indoor
Unit
Outdoor
Unit
Service Diagnosis
Code Indication Description
00
Normal
U0H
Insufficient gas
U2
Over-voltage detection
U4
Signal transmission error (between indoor and outdoor unit)
UA
Unspecified voltage (between indoor and outdoor unit)
A1
Indoor unit PCB abnormality
A5
Freeze-up protection control or high pressure control
A6
Fan motor or related abnormality
C4
Heat exchanger temperature thermistor abnormality
C9
Room temperature thermistor abnormality
E1
Outdoor unit PCB abnormality
E5H
OL activation (compressor overload)
E6H
Compressor lock
E7
DC fan lock
E8
Input over current detection
EA
Four way valve abnormality
F3
Discharge pipe temperature control
F6
High pressure control in cooling
H0
Compressor system sensor abnormality
H6
Position sensor abnormality
H8
DC voltage/current sensor abnormality
H9
Outdoor air thermistor or related abnormality
J3
Discharge pipe temperature thermistor or related abnormality
J6
Heat exchanger temperature thermistor or related abnormality
L3
Electrical box temperature rise
L4
Radiation fin temperature rise
L5
Output over current detection
P4
Heat radiation fin thermistor or related abnormality
H
: Displayed only when system-down occurs.

Troubleshooting

Reference
Page
117
119
94
95
88
89
91
93
93
96
97
98
99
100
101
103
104
106
107
108
109
109
109
111
113
115
109
87

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents