Troubleshooting; Overview: Troubleshooting; Precautions When Troubleshooting - Daikin RZAG71N V1B Series Installer's Reference Manual

Hide thumbs Also See for RZAG71N V1B Series:
Table of Contents

Advertisement

11 Troubleshooting

11.1 Overview: Troubleshooting

11.2 Precautions when troubleshooting

RZAG71~140N
Sky Air Alpha-series
4P695307-1A – 2024.02
This section provides useful information for diagnosing and correcting certain
problems which may occur with the unit. This troubleshooting and related
corrective actions may ONLY be carried out by the installer or service agent.
In case of problems:
See
"8.5 Error codes when performing a test
See the service manual.
INFORMATION
The outdoor unit can generate some transient noises during operation. These sounds
are NOT system malfunctions:
A "shah" noise is heard at the start of defrost operation. This is the sound of the
4-way valve.
A continuous low hissing sound is heard when the system is in cooling or defrost
operation. This is the sound of refrigerant gas flowing through both indoor and
outdoor units.
A gurgling sound is heard after defrost operation. This is the sound of refrigerant
gas flowing through the refrigerant pipe system.
A hissing sound which is heard at the start or immediately after stopping
operation or defrost operation. This is the noise of refrigerant caused by flow
stop or flow change.
This section provides useful information for diagnosing and correcting certain
problems which may occur with the unit. This troubleshooting and related
corrective actions may ONLY be carried out by the installer or service agent.
Before troubleshooting
Carry out a thorough visual inspection of the unit and look for obvious defects such
as loose connections or defective wiring.
DANGER: RISK OF ELECTROCUTION
DANGER: RISK OF BURNING/SCALDING
11
Troubleshooting
|
4
run" [
 68].
Installer reference guide
73

Advertisement

Table of Contents
loading

Table of Contents