Goodman MBE Series Installation Instructions Manual page 14

Blower cabinet
Hide thumbs Also See for MBE Series:
Table of Contents

Advertisement

WARNING
C
NOTES:
1.) Y1 ENABLES LO SPD FAN COOLING
Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES HI SPD FAN HEATING
3.) IF OT1 PJ4 JUMPER IS CUT E/W1 ENABLES
LOW SPD FAN HEATING
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.)DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
2 SPD COOLING ONLY - WITH 2 STAGE HEAT THERMOSTAT
NOTES:
1.) Y1 ENABLES LO SPD FAN COOLING
Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES LOW SPD FAN HEATING
W/W2 WITH OT CLOSED ENABLES HI SPD FAN HEATING
3.) OT1 PJ4 MUST BE CUT FOR THIS CONFIGURATION
OT2 PJ2 MUST BE CUT FOR THIS CONFIGURATION
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.)DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
2 SPD COOLING ONLY - 2 STAGE HEAT (T'STAT ENABLED OT)
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
2-SPD
CONDENSING
UNIT
Y2
Y1
\
Figure 21
OUTDOOR
THERMOSTAT
2-SPD
CONDENSING
UNIT
R
YCON
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH(CFM)
Figure 22
14
ROOM
THERMOSTAT
C
W
1st STAGE HEATER
ROOM
THERMOSTAT
C
R
G
W1
W2
Y1
THERMOSTATS
C
R
Y1
OUTDOOR
HEATPUMP
Y1
COM
W2
ED
W1
W2
C
R
HEATER
24 VAC
W1
W2
HUM
2nd STAGE HEATER
1st STAGE HEATER
HUMIDISTAT
(OPTIONAL)
SEE NOTE 4
Y2
HUMIDISTAT
(OPTIONAL)
SEE NOTE 4
HUMIDISTAT
HUM