TWO-STAGE COOLING WITH CONVENTIONAL TWO-STAGE THERMOSTAT

C
NOTES:
1.) Y1 ENABLES LO SPD FAN COOLING
Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES HI SPD FAN HEATING
3.) IF OT1 PJ4 JUMPER IS CUT E/W1 ENABLES
LOW SPD FAN HEATING
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.)DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
2 SPD COOLING ONLY - WITH 1 STAGE ELECTRIC HEAT
C
Y2
NOTES:
1.) Y1 ENABLES LO SPD FAN COOLING
Y/Y2 ENABLES HI SPD FAN COOLING
2.) E/W1 ENABLES HI SPD FAN HEATING
3.) IF OT1 PJ4 JUMPER IS CUT E/W1 ENABLES
LOW SPD FAN HEATING
4.) CUT HUM PJ6 JUMPER IF USING HUMIDISTAT
STAT OPENS ON HUMIDITY RISE
5.)DIP SWITCH #4 MUST BE IN THE "OFF" POSITION
2 SPD COOLING ONLY - WITH 2 STAGE HEAT THERMOSTAT
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO
MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
2-SPD
CONDENSING
UNIT
E W1
W/W2
CONDENSER
YCON
COM
PLEASE REFER
TO MANUAL
FOR PROPER
DIP SWITCH
(CFM)
CONFIGURATION.
Figure 19
2-SPD
CONDENSING
UNIT
Y1
\
Figure 20
13
ROOM
THERMOSTAT
W
C
E
E
E
THERMOSTATS
HUMIDISTAT
O
OTC
Y1
G
Y/Y2
HUM
OUTDOOR
HEATPUMP
O
W2
ED
Y1
W1
W2
HEATER
24 VAC
S
W1
W2
WI
HUM
DI
P
O
O
1st STAGE HEATER
ROOM
THERMOSTAT
W
C
1st STAGE HEATER
HUMIDISTAT
(OPTIONAL)
SEE NOTE 4
HUMIDISTAT
(OPTIONAL)
SEE NOTE 4