G.
G.

FOLLOW THESE STEPS WHEN BATTERY IS OUTSIDE VEHICLE

A SPARK NEAR THE BATTERY MAY CAUSE BATTERY EXPLO-
SION. TO REDUCE RISK Of A SPARK NEAR BATTERY:
1.
Check polarity of battery posts. POSITIVE (POS, P,+) battery
post usually has a larger diameter than NEGATIVE (NEG, N,
-) post.
2.
Attach at least a 24-inch-long 6-gauge (AWG) insulated
battery cable to NEGATIVE (NEG, N, -) battery post (not
H.
provided).
3.
Connect POSITIVE (RED) charger clamp to POSITIVE (POS,
P,+) post of battery.
4.
Position yourself and free end of cable as far away from
battery as possible - then connect NEGATIVE (BLACK)
charger clamp to free end of cable.
5.
Do not face battery when making final connection.
6.
When disconnecting charger, always do so in reverse
sequence of connecting procedure and break first
connection while as far away from battery as practical.
7.
A marine (boat) battery must be removed and charged on
shore. To charge a battery on the boat requires equipment
specially designed for marine use.
H.
DANGER - Never alter AC cord or plug provided - if it will not fit outlet, have proper outlet installed by a qualified electrician. Improper
connection can result in a risk of an electric shock.
This battery charger is for use on a nominal 120-volt 60 Hz circuit.
I.
1.
These battery chargers are equipped with a self-resetting
circuit breaker. This device protects the charger from
temporary overloads. In the event of an overload, the circuit
breaker will trip open, and after a short cooling off period,
will reset automatically. This process is known as cycling
and can be recognized by an audible clicking sound.
J.
This charger is for use with 12 volt lead-acid batteries. The SE-70MA is for 12 and 24 volt systems.
K.
INDICATION OF PROPER OPERATION TO A DISCHARGED BATTERY
10 Amp 12 Volt setting: The initial charge current should be 10 amps gradually tapering throughout the charge cycle to 5 amps. Though
not indicated, battery voltage will gradually rise to approximately 14.3 volts, then hold constant throughout remainder of charge cycle.
When the battery reaches 14.3 volts and charge current drops to 5 amps the charger will turn off. Initially the battery voltage will drop from
its 14.3 volt level fairly quickly. When 13 volts is reached, the charger will again turn on, until the 14.3 volt, 5 amp condition is met. As this
action continues, on time will decrease to a few seconds while off time increases to a range of several minutes to an hour. on/off times
vary with size, type and condition of battery.
AC POWER CORD CONNECTION INSTRUCTIONS
OPERATION INSTRUCTIONS

OUTPUT VOLTAGE

BUT OTHERWIDE IN GOOD CONDITION
POSITIVE
BATTERY
FIGURE 3: CONNECT NEGATIVE BATTERY
CLIP TO 24 INCH CABLE END
2.
These battery chargers are equipped with an electronic
control circuit which automatically governs the charge rate
to your battery. The charger will satisfactorily charge
Maintenance Free and Conventional batteries.
4
NEGATIVE
CHARGER
24" 6 GAUGE
CABLE
TO GROUNDED
POWER OUTLET
POWER
CORD