6.1.2 Code Specifications
Supported Code Types
The values given here are defined at the scanning reference position. Refer to "6.1.3 Scanning
Performance and Field of View" for details.
(1) BHT-1300Q-CE Series
QR code (Model 1, Model 2) and Micro QR code
Code size
QR code
Max. Ver.32 (360° skew)
Max. Ver.19 (360° skew)
Micro QR code
Max. M4 (360° skew)
iQR code
Code size
Square
Max. Ver.21 (360° skew)
Rectangle
Max. R15 (360° skew)
PDF417
Digits/rows
1 to 15 digits, 4 to 50 rows
Micro PDF417
Digits/rows
1 to 4 digits, 4 to 44 rows
MaxiCode
Module size
30 (29) modules × 33 modules
Data Matrix
Code size
Max.
52 cells × 52 cells (360° skew)
Max.
96 cells × 96 cells (360° skew)
120 cells × 120 cells
*1
*1: Excluding start/stop codes and left/right indicators
*2
*2: Excluding left, middle, and right row address patterns
Barcode / 2D Code Handy
Cell pitch
0.167 mm
0.25 mm
0.2 mm
Cell pitch
0.25 mm
0.25 mm
Module dimensions
0.167 mm min.
Module dimensions
0.167 mm min
Module pitch
0.88 mm
Cell pitch
0.20 mm
0.25 mm
49