Maintenance And Service; Annual Service; Monthly Maintenance - Beckett CF1000 Manual

Beckett oil burner cf1000
Hide thumbs Also See for CF1000:
Table of Contents

Advertisement

Maintenance and Service

Annual Professional
Service Required
Tampering with or making incorrect
adjustments could lead to equipment
malfunction and result in asphyxia-
tion, explosion or fi re.
Do not tamper with the burner or controls or make
any adjustments unless you are a trained and qualifi ed
service technician.
To ensure continued reliable operation, a qualifi ed
service technician must service this burner annually.
More frequent service intervals may be required in dusty
or adverse environments.
Operation and adjustment of the burner requires technical
training and skillful use of combustion test instruments
and other test equipment.

Annual service

— by qualifi ed service techni-
cian
Have the burner inspected, tested and started at least annually
by a qualifi ed service technician. This annual test/inspection
should include at least the following:
Replace the oil supply line fi lter. The line fi lter cartridge
must be replaced to avoid contamination of the fuel unit
and nozzle.
Inspect the oil supply system. All fi ttings should be leak-
tight. The supply lines should be free of water, sludge and
other restrictions.
Remove and clean the pump strainer if applicable.
Replace the nozzle with the exact brand, pattern, gph, fl ow
rate and spray angle.
Clean and inspect the electrodes for damage, replacing any
that are cracked or chipped.
Check electrode tip settings. Replace electrodes if tips are
rounded.
Form 6104 BCF10-R06
Inspect the igniter spring contacts.
Clean the cad cell lens surface, if necessary.
Inspect all gaskets. Replace any that are damaged or would
fail to seal adequately.
Inspect the combustion head and air tube. Remove any car-
bon or foreign matter. Replace all damaged units with exact
parts.
Clean the blower wheel, air inlet, air guide, and burner
housing of any lint or foreign material.
If motor is not permanently lubricated, oil motor with a few
drops of SAE 20 nondetergent oil at each oil hole. DO NOT
over oil motor. Excessive oiling can cause motor failure.
Check motor current. The amp draw should not exceed the
nameplate rating.
Check all wiring for secure connections or insulation
breaks.
Check the pump pressure and cutoff function.
Check primary control safety lockout timing.
Check ignition system for proper operation.
Inspect the vent system and chimney for soot accumulation
or other restriction.
Clean the appliance thoroughly according to the manufac-
turer's recommendations.
Check the burner performance. Refer to the section "Set
combustion with test instruments".
It is good practice to make a record of the service performed
and the combustion test results.

Monthly maintenance

Observe combustion air openings and vent system for
integrity. Openings must be clean and free of obstructions.
Check oil lines and fi ttings to verify there are no leaks.
Observe burner ignition and performance to verify smooth
operation.
Shut the system down if you observe abnormal or
questionable operation. Call a qualifi ed service agency for
professional inspection and service.
— by owner
17

Advertisement

Table of Contents
loading

Table of Contents