Beckett CF 2300A Instruction Manual

Oil burner

Advertisement

MODEL
MODEL
2300A
MODEL
MODEL
MODEL
CF
Instruction Manual
Low/High Operation
Firing rate: 7.0 – 19.9 GPH
Motor voltage: 120 / 60 Hz std.
Thank you for purchasing a
Beckett burner. With proper care and
regular maintenance, it will provide
years of trouble-free service. Please
take a few minutes to read the section
entitled "To the owner" inside this
manual. Then, keep the manual in a
safe place where it can be easily
located if needed by your professional
service technician.
Oil
Burner

Advertisement

Table of Contents
loading

Summary of Contents for Beckett CF 2300A

  • Page 1 Firing rate: 7.0 – 19.9 GPH Motor voltage: 120 / 60 Hz std. Thank you for purchasing a Beckett burner. With proper care and regular maintenance, it will provide years of trouble-free service. Please take a few minutes to read the section entitled “To the owner”...
  • Page 2: Please

    Contacting Beckett for service information or parts - Please record the burner serial number (and have available when calling or writing). This equipment must be installed, adjusted...
  • Page 3: Table Of Contents

    Instruction Manual – Model CF2300A Oil Burner Contents Warranty Beckett warrants its equipment to those who have purchased it for resale, including your Please . . . read this page first ....2 dealer. If you have any problems with your equipment or its installation, you should contact your dealer for assistance.
  • Page 4: Pre-Installation Checklist

    Instruction Manual – Model CF2300A Oil Burner Pre-installation checklist Combustion air supply Vent system • The burner requires combustion air and ventilation air for • The flue gas venting system must be in good condition reliable operation. Assure that the building and/or com- and must comply with all applicable codes.
  • Page 5: Verify Firing Rate

    Instruction Manual – Model CF2300A Oil Burner Verify firing rate Figure 2 – Air tube mounting dimensions E Insertion depth • Refer to appliance manufacturer’s instructions (if avail- G Air tube to inside of chamber able) for firing rate and nozzle selection. Otherwise, the –...
  • Page 6: Mount The Burner

    Instruction Manual – Model CF2300A Oil Burner Mount the burner Figure 4 – Nozzle and nozzle line assembly Mount flange(s) on air tube • This section does not apply to burners with welded flanges. • Do not install air tube on burner. •...
  • Page 7: Set Dimension Z

    Instruction Manual – Model CF2300A Oil Burner Figure 5 – Nozzle line assembly in burner Figure 6 – Adjusting plate assy. Measure dimension from front (flat) face of head to end of air tube, as shown. 2308-1 Legend (Figures 5 and 6) a Adjusting plate assembly b Spline nut for securing nozzle line c Bottom acorn nut...
  • Page 8: Connect Fuel Line(S)

    Instruction Manual – Model CF2300A Oil Burner Connect fuel line(s) Figure 8a – One-pipe oil flow, low fire, “ ” pump • Install the oil lines using the following guidelines. Failure to comply could lead to equipment damage and present a risk of severe personal injury, death or substan- tial property damage due to leakage of oil 300 psig...
  • Page 9: Burner Fuel Flow

    Instruction Manual – Model CF2300A Oil Burner Figure 9a – Two-pipe oil flow, low fire, “ ” pump • Use continuous lengths of heavy-wall copper tubing, routed under the floor where possible. Do not attach fuel lines to the appliance or to floor joists if possible. This reduces vibration and noise transmission problems.
  • Page 10: Wire The Burner

    Instruction Manual – Model CF2300A Oil Burner Wire the burner Do not by-pass any safety control. Figure 10 for a typical wiring diagram, with R8184 oil By-passing a safety control could result in primary, for reference purposes only. The CF2300A burner is severe personal injury, death or substantial available with many different wiring configurations.
  • Page 11: Sequence Of Operation - Typical

    Instruction Manual – Model CF2300A Oil Burner Sequence of operation — typical NOTE: The following sequence is based on using a type 6. When the damper motor end switch is tripped, oil valve fuel unit, with pump-mounted by-pass valve. The by-pass valve ) is activated, stopping by-pass flow inside the fuel operation is reversed for a type fuel unit.
  • Page 12: Adjusting Plate Assembly

    Instruction Manual – Model CF2300A Oil Burner Prepare the burner for start-up - continued Z dimension Figure 11 – Adjusting plate initial setting, typical • Should be set per these instructions (see page 7). The top acorn nut ( , item ) should never be loosened Figure 11 once the...
  • Page 13 Instruction Manual – Model CF2300A Oil Burner Figure 12 – Air damper and damper motor assembly 2309-1 2309-2 Table 5 – Initial air adjusting plate settings Legend (Figure 12) (damper position) a Damper motor – do not adjust internal cam Approximate Firing rate, gph b Arm assembly...
  • Page 14: Start The Burner

    Instruction Manual – Model CF2300A Oil Burner Start the burner Do not proceed unless all prior steps in this Place the end of the tube in a container to catch the manual have been completed. Failure to oil. Then loosen the fuel unit air vent valve. comply could result in severe personal injury, Tighten the air vent valve after all air has been purged.
  • Page 15: Maintenance And Service

    Instruction Manual – Model CF2300A Oil Burner Set low-fire air b. Slowly rotate the air adjusting plate (increase the amount of air) as the damper drives to high-fire. 1. Loosen the air adjusting plate ( , item ) screw Figure 12 c.
  • Page 16: Replacement Parts

    Motor relay (not shown) Specify relay used 12.44" Diameter 13.92" Diameter U.S.A.: P . O. Box 1289 Elyria, Ohio 44036 800-645-2876 440-327-1060 FAX 440-327-1064 Canada: R. W. Beckett Canada, Ltd. 430 Laird Road Guelph, Ontario, N1G 3X7 800-665-6972 FAX 519-763-5656 Form 6104 BCF-23-R0399...