Sanyo DSR - 300 Instruction Manual page 82

Digital video recorder
Table of Contents

Advertisement

1
INTERFACE SPECIFICATIONS
(when optional interface board is installed)
RS-232C
Pin No.
Signal
1
2
RXD
3
TXD
4
5
GND
6
7
RTS
8
9
Data format
Mode
Asynchronous
Character length
8 bits
Data transmission
2400, 4800, 9600, 19200 bps
speed
Parity check
None
Stop bit
1
Only the data transfer speed can be set. ( P. 69)
Communication protocol
Communication is carried out in units of 1 byte. After the
PC has transmitted a single byte, it waits for a response
from the unit before sending the next byte.
An ON (F6) command is sent as the start command, and
the unit will continue to accept commands until an OFF
(F7) command is sent as the end command. Whenever the
unit receives a command, it returns an ACK (OA).
English
1
2
3
4
5
6
7
8
9
Operation
Signal direction
PC → Unit
Reception
Unit → PC
Transmission
Ground
Transmission
Unit → PC
request
RS-485
When using RJ-11 connector
Pin No.
Connector A signal
1
Not used
2
Not used
3
4
5
Not used
6
Not used
A: Non-inverting driver output, non-inverting receiver input
B: Inverting driver output, inverting receiver input
Communication wire: 2-core wire
Communication system: Half duplex
Data format
Mode
Asynchronous
Character length
8 bits
Data transmission
2400, 4800, 9600, 19200 bps
speed
Parity check
None
Start bit
1
Stop bit
1
To set the data transmission speed, address and
termination switch, see "Settings for RS-232C and RS-
485" ( P. 69).
Communication protocol
A proprietary Sanyo protocol (SSP: Security Serial
Protocol) is used. Use of a Sanyo system controller is
recommended.
81
1
6
Connector B signal
Not used
Not used
A
B
B
A
Not used
Not used

Advertisement