9.6. To clean the element assembly:
9.6.1. Refer to Section 12, Maintenance: "9.5. To renew the element
assembly" and remove the element assembly.
9.6.2. Unclip the thermal switch clip and remove the element retaining ring and
the seal.
9.6.3. Immerse the element assembly up to the flange in a proprietary plastic
kettle descalent. Follow the descalent manufacturer's instructions.
DO NOT allow the solution to come into contact with the element
assembly terminals or the plastic components.
Note! Heater elements may be damaged by excessive use of descalent
solution.
9.6.4. Refer to Section 12, Maintenance: "9.4. To renew the tank body/
sensor assembly" and remove the tank body/sensor assembly.
9.6.5. Rinse out the tank body/sensor assembly in cold water to remove any
limescale.
DO NOT immerse tank body/sensor assembly in descalent.
9.6.6. Refit in reverse order. Make sure that the thermal switch clip is fitted
correctly.
45