Troubleshooting; Check Before And After Troubleshooting; Troubleshooting 9-1. Check Before And After Troubleshooting - Sanyo CH0951 Technical & Service Manual

Split system air conditioner
Hide thumbs Also See for CH0951:
Table of Contents

Advertisement

9. TROUBLESHOOTING

9-1. Check before and after troubleshooting

WARNING
Hazardous voltage can cause ELECTRIC SHOCK or
DEATH. Disconnect power or turn off circuit breaker
before you start checking or servicing.
9-1-1. Check power supply wiring.
Check that power supply wires are correctly connected to terminals No. 7 (L1) and No. 8 (L2) on the terminal
plate in the outdoor unit.
9-1-2. Check inter-unit wiring.
Check that inter-unit wiring is correctly connected to the indoor unit from the outdoor unit.
9-1-3. Check power supply.
Check that voltage is in specified range (±10% of the rating).
Check that power is being supplied.
9-1-4. Check lead wires and connectors in indoor and outdoor units.
Check that coating of lead wires is not damaged.
Check that lead wires and connectors are firmly connected.
Check that wiring is correct.
Outdoor
Inter–unit
Indoor
unit
power wiring
unit
1
1
2
2
3
3
4
4
5
5
6
6
7
8
Inter–unit
control wiring
G
G
G
Ground
Power supply :
L1
Single- phase, 60Hz
L2
115V.....CH0951,CH1251
230/208V............CH1852
Ground
54

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ch0952Ch1251Ch1852Khs1852-sKhs1251Khs1852 ... Show all

Table of Contents