Power Supply; Inputs/Outputs; Communications; Connection - Murphy CONNECT Operation Manual

Telematics for powercore
Table of Contents

Advertisement

Murphy CONNECT Specifications

Power Supply

Operating Voltage: 9-36 VDC, reverse battery polarity protected
Max Voltage: -40 to +60 VDC
Power Consumption:
12 VDC: Transmitting: 265mA, Idle: 135mA, Off: 0.5mA (Using IGN to turn off),
On: ~175mA Avg.
24 VDC: Transmitting: 135mA, Idle: 90mA, Off: 0.5mA (Using IGN to turn off),
On: ~115mA Avg.

Inputs/Outputs

(1) Digital, Shared (Future Use)

Communications

(1) CAN: J1939 (Future Use)
(1) RS485: Modbus RTU
(1) Wi-Fi:2.4GHz 802.11 b/gn (Troubleshooting)
(1) Cellular (LTE)
(1) GPS (Location Services)

Connection

Connection:
8 Position: Amphenol AT06-08S
Antenna: SMA (Supplied 2 Wire Dual Cellular LTE and GPS)
Mating Connector:
8 Position: Amphenol AT04-08PA
Deutsch DT04-08PA

Physical / Environmental

Enclosure Material: Polycarbonate
Dimensions (WxHxD): 5.06 x 7.56 x 1.55 in. (129 x 192 x 39 mm)
IP Rating: IP67
Operating & Storage Temperature: -30°C to +80°C (-22°F to +176°F)
Vibration: 8.17 Grms (5-2000 Hz), 3-axes random
(Vibration specification was met without the use of rubber isolation mounts)
Shock: ±25G, 3 axes
(Vibration specification was met without the use of rubber isolation mounts)
Section 40
2018-10-08
23
00-02-1165

Advertisement

Table of Contents
loading

Table of Contents