Installation Guide
1000 Hz Control Card MK-I
VLT® AutomationDrive FC 302 Series
1 Introduction
1.1 Purpose of this Installation Guide
This installation guide provides information for quick installation of the control card in VLT® AutomationDrive FC 302 series.
Update to 1000 Hz output frequency. The drive is subject to export control, ECCN 3A225.
1.2 Trademarks
®
VLT
is a registered trademark for Danfoss A/S.
1.3 Item Supplied
VLT® FC 302 1000 Hz Control Card MK-I (code number: 134B6628).
1.4 Tools
Torx 10 screwdriver.
Flat-head screwdriver.
1.5 Additional Items Required
VLT® AutomationDrive FC 302.
Danfoss A/S © 2018.11
AN281754171207en-000101 / 130R0878 | 1

Advertisement

loading

Summary of Contents for Danfoss 1000 Hz Control Card MK-I

  • Page 1 Update to 1000 Hz output frequency. The drive is subject to export control, ECCN 3A225. 1.2 Trademarks ® is a registered trademark for Danfoss A/S. 1.3 Item Supplied • VLT® FC 302 1000 Hz Control Card MK-I (code number: 134B6628). 1.4 Tools • Torx 10 screwdriver. • Flat-head screwdriver.
  • Page 2: Qualified Personnel

    Installation Guide | 1000 Hz Control Card MK-I Safety 2 Safety 2.1 Qualified Personnel Correct and reliable transport, storage, installation, operation, and maintenance are required for the trouble-free and safe operation of the drive. Only qualified personnel are allowed to install and operate this equipment.
  • Page 3 C A U T I O N When the new control card is installed in the drive by a local Danfoss company or a local Danfoss partner company, the extra 1000 Hz label, which is in the box, must be placed visible on the drive. The label indicates that the drive is updated to run with maximum 1000 Hz speed.
  • Page 4 Installation Guide | 1000 Hz Control Card MK-I Safety N O T I C E The control card is based on the MK-I control card (130B1109), and does not have all the new functions which are in the new MK-II control card. Furthermore, new software cannot be flashed into this control card.
  • Page 5: Installation

    Installation Guide | 1000 Hz Control Card MK-I Installation 3 Installation 3.1 Replacing the Control Card Procedure 1. Remove the LCP and the blind cover. 1 LCP 2 Blind cover Illustration 2: LCP and Blind Cover Illustration 3: Removing LCP Danfoss A/S ©...
  • Page 6 Installation Guide | 1000 Hz Control Card MK-I Installation Illustration 4: Removing Blind Cover 2. Remove the LCP cradle. Illustration 5: Removing LCP Cradle 3. Remove all control cables from the metal bracket (spring-loaded). 4. Remove any A, B, or C options that may be installed.
  • Page 7 Installation Guide | 1000 Hz Control Card MK-I Installation 1 Location of A option 2 Location of B option 3 I/O terminals Illustration 6: Location of Options and I/O Terminals 6. Unscrew the 3 T10 screws and remove the cable shield.
  • Page 8 Installation Guide | 1000 Hz Control Card MK-I Installation 1 T10 screws 2 EMC shield Illustration 8: Screws and EMC Shield 10. Unscrew the 3 T10 screws and remove them. 11. Gently remove the control card from the upper-right socket. Avoid overbending and contact with electronic components.
  • Page 9 Installation Guide | 1000 Hz Control Card MK-I Installation Danfoss A/S © 2018.11 AN281754171207en-000101 / 130R0878 | 9...
  • Page 10 Installation Guide | 1000 Hz Control Card MK-I Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.