Editorial changes. Installation of VLT® Sensorless Safety MCB 159 added. 1.4 Type Approvals and Certifications The following list is a selection of possible type approvals and certifications for Danfoss drives: N O T I C E Drives of enclosure size T7 (525–690 V) are not UL listed.
Check whether the required Performance Level “PLr”, determined in the risk assessment, is achieved by the selected system for each safety function used. Check the calculation using the SISTEMA SW Tool of IFA (Institute for Occupational Safety & Health). Danfoss provides a component library which can be used for the calculation.
The Safe Limited Speed is given as speed limit in parameter 42-51 Speed Limit. The value for the cut-off speed partly depends on the motor that is being used. A suggested value from the MCT 10 Set-up Software calculates a value for which Danfoss guarantees functionality.
Unauthorized modifications made to the firmware can lead to injury and equipment damage and voids the warranty. Furthermore, Danfoss cannot be held liable for any consequences third-party changes may have on the functional safety. Only have Danfoss change the firmware.
7.3.4 Copying Safe Parameter Set-up. Prerequisites: Reset all option parameters to factory setting to avoid trips caused by replacement of the safety option. Order a new safety option at Danfoss. Procedure 1. Replace the defective option, see 4.1 Installing the Option.
Page 102
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.