Danfoss VLT Safety Option MCB 150 Installation Manual

Hide thumbs Also See for VLT Safety Option MCB 150:
Table of Contents

Advertisement

Installation Guide
VLT® Safety Option MCB 150/151

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss VLT Safety Option MCB 150

  • Page 1 Installation Guide VLT® Safety Option MCB 150/151...
  • Page 3: Table Of Contents

    Operation and Requirements 3.5.2 Safety Functions 3.5.3 Safe Torque Off - STO 3.5.4 Safe Stop 1 - SS1 3.5.4.1 SS1 Delay 3.5.4.1.1 Selecting the SS1 Settings 3.5.4.2 SS1 Delay with S-ramp Stop Profile Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 3...
  • Page 4 4.2.3 Proximity Switch 4.2.4 VLT® Sensorless Safety MCB 159 4.2.4.1 Connecting a VLT® Sensorless Safety MCB 159 (MCB 151 Only) Application Examples 4.3.1 Connecting Safe Digital Inputs 5 Commissioning Before Commissioning 4 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 5 Checking Effectiveness of Safety Functions 7.4.3 Safety Functions in the Drive 8 Warnings and Alarms Fault Types and Messages 8.1.1 Messages Warnings and Alarms 8.2.1 Safety Option Warning 8.2.2 Safety Option Reset Message Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 5...
  • Page 6 Digital Output (Safe Output) 9.3.2 24 V Supply Output Other Specifications 9.4.1 Ground I/O Section 9.4.2 Cable Cross-sections 9.4.3 Reset Characteristics 9.4.4 Response Time 9.4.5 Safety Characteristic Data 10 Appendix 10.1 Abbreviations 10.2 Conventions 6 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 7: Introduction

    3 Test phase: Use the commissioning report generated via the MCT 10 Safe Plug-in. Illustration 1: System Overview Also refer to www.danfoss.com/en/search/?filter=type%3Adocumentation%2Csegment%3Adds for more information. 1.3 Document Version This manual is regularly reviewed and updated. All suggestions for improvement are welcome. See document version and changes applied in table Danfoss A/S ©...
  • Page 8: Type Approvals And Certifications

    Editorial changes. Installation of VLT® Sensorless Safety MCB 159 added. 1.4 Type Approvals and Certifications The following list is a selection of possible type approvals and certifications for Danfoss drives: N O T I C E Drives of enclosure size T7 (525–690 V) are not UL listed.
  • Page 9: Legal Information An Safety

    N O T I C E Indicates a property damage message. 2.4 Qualified Personnel The products must only be assembled, installed, programmed, commissioned, maintained, and decommissioned by persons with proven skills. Persons with proven skills: Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 9...
  • Page 10: Responsibilities Of Users Of Pds(Sr)

    Disconnect the drive from the mains whenever personal safety considerations make it necessary to avoid unintended motor start. Check that the drive, motor, and any driven equipment is in operational readiness. 10 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 11 N O T I C E The drive has more voltage sources than L1, L2, and L3 when load sharing (linking of DC link) or external 24 V DC are installed. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 11...
  • Page 12: Risk Assessment

    Programming the application software and the safety option configurations in accordance with the information in this manual. • Access to the control system. • Analyzing all configuration settings and selecting the proper setting to achieve the required safety rating. 12 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 13: Functions And Systems Overview

    (when the motor speed of the monitored device is below the set switch point). When the speed exceeds the set value, indicating a too high (dangerous) speed, the safety output is low. The drive: Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 13...
  • Page 14: Behavior Of Holding Brake

    Typical safety functions are described in more detail in EN ISO 13849-1, section 5, Specification of Safety Functions. The safety functions for drive systems are described in IEC 61800-5-2. 14 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 15: Functions

    Check whether the required Performance Level “PLr”, determined in the risk assessment, is achieved by the selected system for each safety function used. Check the calculation using the SISTEMA SW Tool of IFA (Institute for Occupational Safety & Health). Danfoss provides a component library which can be used for the calculation.
  • Page 16: Simultaneous Activation Of Safety Functions

    If 2 safely limited speed functions are active at the same time, the function with the lowest speed limit has higher priority than the function with higher speed limit. If 2 equal safety functions have to be configured, they must be parameterized as SS1-a and SS1-b, or as SLS-a and SLS.b. 16 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 17: Functional Proof Tests

    The functional safety standards require that functional proof tests are performed on the equipment used in the system. Proof tests are performed at user-defined intervals and depend on PFD and PFH values. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 17...
  • Page 18: Pfd And Pfh Definitions

    Has a simple language setting for the user interface. A PDF file and a commissioning report can be generated for documentation of the project and all its settings. 3.3 Unit Features The safety option has the following features: 18 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 19: Front View

    Illustration 5: VLT® Safety Option MCB 150 MCB 151 Option B 130B3290 Safe Option SW. ver. xx. xx HTL Enc.interface LED: 9 10 Y31/ Illustration 6: VLT® Safety Option MCB 151 Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 19...
  • Page 20: Categories Of Safe Stop

    Motor decelerates. Monitoring of deceleration ramp and Safe Torque Off following 0 speed, or Safe Torque Off at the end of a deceleration time. Stop category 1 to EN IEC 60204-1. • Safely limited speed (SLS) Prevents exceeding a defined speed value. The safety option implements the following safety functions 20 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 21: Safe Torque Off - Sto

    Thus, it prevents the drive from generating the voltage required to rotate the motor, see illustration 7. The function allows performing maintenance work on non-electrical parts of the machinery without switching off the power supply to the drive. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 21...
  • Page 22: Safe Stop 1 - Ss1

    Using SS1 Delay may result in the motor still spinning when the Safe Torque Off is activated. The risk analysis for the machine must indicate that this behavior can be tolerated. An interlock may be required. 22 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 23: Selecting The Ss1 Settings

    3.5.4.1.1 Selecting the SS1 Settings Procedure 1. Enter parameter 42-41 Ramp Profile. Select: [0] Linear, if the ramp must follow a linear curve. [2] S-ramp Const Time, if the ramp should follow an S-ramp. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 23...
  • Page 24: Ss1 Delay With S-Ramp Stop Profile

    A Actual frequency 1 Activation of SS1 Ramp Delay 2 Activation of STO 3 Parameter 42-42 Delay Time 4 Parameter 42-43 Delta T 5 Parameter 42-48 S-ramp Ratio at Decel. Start 24 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 25: Ss1 Ramp

    Table 4: Parameters for SS1 Ramp Slope Parameter Unit Range Default Parameter 42-44 Deceleration Rate RPM/s 1–30000 RPM/s 1500 RPM/s Parameter 42-45 Delta V 1–10000 RPM 120 RPM Parameter 42-46 Zero Speed 1–600 RPM 10 RPM Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 25...
  • Page 26: Ss1 Ramp Time

    Table 5: Parameters for SS1 Ramp Time Parameter Unit Range Default Parameter 42-47 Ramp Time 0.1–3600.0 s 1.0 s Parameter 42-45 Delta V 1–10000 RPM 120 RPM Parameter 42-46 Zero Speed 1–600 RPM 10 RPM 26 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 27: Safely Limited Speed

    The Safe Limited Speed is given as speed limit in parameter 42-51 Speed Limit. The value for the cut-off speed partly depends on the motor that is being used. A suggested value from the MCT 10 Set-up Software calculates a value for which Danfoss guarantees functionality.
  • Page 28: Sls Without Ramp

    4 Delta speed limit 5 Activation of failure function set in parameter 42-52 Fail Safe 6 Fixed value of 120 RPM in parameter 42-19 Zero Speed Limit Reaction Illustration 12: SLS without Ramp 28 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 29: Sls With Ramp

    When the Safely Limited Speed function is deactivated, the speed limits are ramped up back to the values defined in parameter group 3-1* References. The actual speed then returns to the reference value if it was limited by this function. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 29...
  • Page 30: Configuring Sls Operation

    7 Activation of failure function set in parameter 42-52 Fail Safe Reaction Illustration 14: SLS with Ramp Table 7: Parameters for SLS with Ramp Parameter Unit Range Default Parameter 42-50 Cut Off Speed 120–10000 RPM 270 RPM 30 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 31: Inputs And Output

    0 signal (0 V) at the input: Activates the safety function. • 1 signal (+24 V) at the input: Does not activate the safety function. • 0/1 transition at the DI2 input if configured to reset: Resets the safety option. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 31...
  • Page 32: Reset Input (Di2)

    2 reset for acknowledgment of the active safety function. Alarms caused by the drive must be reset before an alarm can be reset on the safety option. 32 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 33: Signal Filtering

    When interconnecting the safe input of the option with a safe output of a control module, the option could respond to these test signals. A signal change during a test pulse pattern usually lasts 1 ms. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 33...
  • Page 34: Zero Speed Timer Error Detection

    STO function is selected. The safety option monitors the regular test interval of its safety-relevant circuits using a time module. 34 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 35: Safety Parameter Settings

    Safe Option to restart the safety option after internal failure without power cycling the drive. 3.7.2 Compatibility between Safety and Drive Function The safety option is compatible with all VLT AutomationDrive FC 302 drives. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 35...
  • Page 36 The following software versions are required as a minimum for using MCB 150/151: • LCP software version 7.0. • VLT AutomationDrive FC 302 firmware version 6.64. All drives, options, and control mode combinations not listed above are not allowed. 36 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 37: Installation

    VLT AutomationDrive FC 302/FC 302 Operating Guide. • Tool-Tip help for the configuration tool MCT 10 Safe Plug-in. Only use the safety option with the following drives: • VLT AutomationDrive FC 302 from software version 6.64. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 37...
  • Page 38: Protected Cable Installation

    Safety Option MCB 150/151 and X44/12 on the control card) in an IP54 enclosure as per IEC 60529. A A-option slot B B-option slot D D-option slot 1 LCP frame Illustration 17: How to Fit the Safety Option 38 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 39 5. Connect the safe output S37 on the safety option to terminal 37 on the control card (maximum length of this wire is 100 mm (3.9 in)). 6. Connect the control cables to the safety option and relieve the cable by the enclosed cable strips. Follow the guidelines in 4.1.5 General Wiring Guidelines. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 39...
  • Page 40 Illustration 19: Connecting the Shielded Wire 7. Remove the knock-out in the extended LCP frame so that the option fits under the frame. 8. Fit the extended LCP frame and terminal cover. 40 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 41: General Wiring Guidelines

    Only allow qualified personnel to do the wiring of the equipment. 4.1.5 General Wiring Guidelines Inputs Use appropriate wiring to exclude short circuits between the inputs or to a supply line. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 41...
  • Page 42 Retain cable shields for both power cables and for signal and data cables using the appropriate EMC clamps. The shield clamps must connect the shield to the EMC shield bar of the shield support element for control cables through a low inductive connection through a large surface area. 42 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 43: Connector Pin Assignment

    24 V Power output Supply GND STO enable MCB 150 Option B 130B3280 Safe Option SW. ver. xx. xx TT L Enc.interface LED: 9 10 Y30/ Illustration 22: Nameplate MCB 150 Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 43...
  • Page 44: Encoder

    The maximum cable length for TTL encoders used as bipolar encoder (in this case both signals A/nA or B/nB) is 150 m (492 ft). The minimum cross-section of the power supply conductor is 0.75 mm (18 AWG). 44 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 45: Encoder Wiring Examples

    See examples of how to connect encoder power and encoder signals in illustration 25 illustration FC 302 MCB 151 24 V Illustration 25: Y31/Connecting Power and Encoder Signals to HTL Encoder (VLT® Safety Option MCB 151) Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 45...
  • Page 46: Proximity Switch

    Y/31 Connecting VLT® Safety Option MCB 151 to Proximity Switch (only HTL) N O T I C E Shield and terminate the proximity switch cable to chassis at both ends (at the proximity switch side and at the option side). 46 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 47: Vlt® Sensorless Safety Mcb

    It can easily replace a speed sensor in applications where typically proximity switches are used as a speed feedback. Only 1 wire connects the MCB 159 option to the MCB 151. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 47...
  • Page 48: Connecting A Vlt® Sensorless Safety Mcb 159 (Mcb 151 Only)

    4.2.4.1 Connecting a VLT® Sensorless Safety MCB 159 (MCB 151 Only) Procedure 1. Connect the cable marked TER4:ENC A on the MCB 159 to terminal 4 on the MCB 151. FC 302 MCB 151 MCB 159 24 V 48 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 49: Application Examples

    A Drive Illustration 32: Connecting an Electronic Sensor, for Example Safety Light Curtain MCB15x A Actuator B Switch C Drive Illustration 33: Connecting 1 NO/1 NC Sensor, for Example Magnetic Switch Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 49...
  • Page 50 (for example, in separate wire ways or conduit). According to the definition of European standard EN ISO 13849-1, a 1-channel E-stop could be used in applications where PL c or less (b or a) has been determined via a risk-assessment procedure. 50 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 51 E-Stop Illustration 36: Example of Multiple Drives in Daisy Chain Up to 3 drives may be connected in a daisy chain. Total cable length must not exceed 30 m (98.4 ft). Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 51...
  • Page 52: Commissioning

    N O T I C E Only LCP SW version 7.0 or newer is supported. Prerequisites: The following components are required to perform the necessary steps for commissioning the safety option: 52 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 53: Initial Commissioning

    D On multi-axis systems, the safety option can be selected individually for the download. The configuration is distributed to the safety options via the MCT 10 Set-up Software. When the configuration file is downloaded, the LCP reads SO Custom. completed. During download, the following is checked in the configuration: Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 53...
  • Page 54: Safety Option Customization

    Off Remote SO Req.RESET MCT 10 customization of the safety option is complete. Status !1(1) 0 RPM None 0.00KW SO Custom. completed SO RESET required! !Safe Stop [W68] Off Remote SO Req.RESET 54 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 55: Setting Up The Encoder

    The test objective is to verify proper implementation (forced dormant error detection measures) and to examine the response of specific monitoring functions to the explicit input of values outside tolerance limits. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 55...
  • Page 56: Operation

    LED1, LED2, and LED4 are lit. During operation: • Any pulse edge change at the safety option safe input is monitored. • The safety functions are performed in accordance with the configuration. 56 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 57: General Parameter Set-Up

    The safety option is configured with the commissioning software MCT 10 Set-up Software via a Safe Plug-in. The Safe Plug-in in the commissioning software is available as default from version 3.18. The commissioning software provides the following menu items for the safety option: Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 57...
  • Page 58: Password Protection

    Change the safety option password if there is any indication of manipulation. 6.1.3.1 Resetting the Password Context: N O T I C E Resetting the password resets all option parameters to factory default. 58 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 59: Reset And Status Over Fieldbus

    N O T I C E Only active safe function is set in Safety Option Status. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 59...
  • Page 60 Safe function pending General reset Customization_confirmed Customization_aborted Customization_requested Suspension of speed monitoring PUST warning DI_1_offline_warning DI_2_offline_warning Error code Error code Error code Error code Error code Error code Error code Error code 60 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 61 Customization confirmed No change in state. Customization confirmed by user. Customization aborted No change in state. Customization aborted by user. Customization requested No change in state. Customization is requested by the user. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 61...
  • Page 62 Blank initial state 0 (inactive/1 (active) Unused Table 13: Bit Functions, Status 2 But number Bit name Value Function 00-01 DI1 safety status Inactive Active Pending 02-03 DI2 safety status Inactive Active Pending 62 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 63: Parameter List

    Time period where the option is al- u_int16 Speed Tim- lowed to be below 120 RPM when SLS is active before STO is activated. 42-19 Zero Fixed 120 RPM u_int16 Speed Lim- Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 63...
  • Page 64 DI1_A 42-33 Pa- Visible String, SafeSet1 Name of the safe parameter Set (must rameter length: 8 be 8 characters to avoid a bad customi- Set Name zation data error). 64 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 65 (parameter 42-42 Delay Time) at Decel. where the deceleration torque decrea- ses. The larger the percentage value, the greater the jerk compensation ach- ieved, and thus the lower the torque jerks in the application. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 65...
  • Page 66 Can only be selected in param- eter 0-23 Display Line 2 Large and parameter 0-24 Display Line 3 Large. 42-89 Cus- 0.00–99.99 1.00 Stores the customization file version. u_int16 tomization File Version 66 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 67 Possibility to restart option after inter- – u_int8 start Safe nal failure without power cycling the [1] Yes Option drive. Refer to VLT AutomationDrive FC 302 Operating Guide for a comprehensive parameter list. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 67...
  • Page 68: Service And Repair

    Unauthorized modifications made to the firmware can lead to injury and equipment damage and voids the warranty. Furthermore, Danfoss cannot be held liable for any consequences third-party changes may have on the functional safety. Only have Danfoss change the firmware.
  • Page 69: Replacement Of Safety Option

    If the configuration changes, the drive freezes the hardware configuration, trips, and refuses to start up. Thus avoiding any unintended parameter changes. When replacing the safety option, note the following: Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 69...
  • Page 70: Copying Safe Parameter Set-Up

    7.3.4 Copying Safe Parameter Set-up. Prerequisites: Reset all option parameters to factory setting to avoid trips caused by replacement of the safety option. Order a new safety option at Danfoss. Procedure 1. Replace the defective option, see 4.1 Installing the Option.
  • Page 71 ([1] Enabled) If the entered password is wrong, this overlay message is shown for some seconds. Then the pass- word can be entered again. 0 RPM None 1(1) Password rejected ([1] Enabled) Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 71...
  • Page 72 If selecting [SO:…], the customization of the safety option is completed and a reset is required to finalize this procedure. Status !1(1) 0 RPM None 0.00KW SO Custom. completed SO RESET required! !Safe Stop [W68] Off Remote SO Req.RESET 72 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 73 Press [OK] to complete the customization of the safety option. A reset is required to finalize this procedure. Status !1(1) 0 RPM None 0.00KW SO Custom. completed SO RESET required! !Safe Stop [W68] Off Remote SO Req.RESET Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 73...
  • Page 74: Commissioning Test

    The test objective is to verify proper configuration of the defined safety functions and of test mechanisms and to examine the response of specific monitoring functions to the explicit input of values outside tolerance limits. Test safety-configured monitoring functions running in the final set-up. 74 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 75: Safety Guidelines

    7.4.3 Safety Functions in the Drive After making, for example, LCP copy of safe parameters, a commissioning test is required. Use these short versions of the commissioning test reports to follow and approve the test sequence. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 75...
  • Page 76 The SS1 ends with an STO warning or alarm, depending on the configuration. 7. Deselect SS1. 8. Check the following: • Safety Func. Pending is shown. • SS1 is deselected and inactive. 76 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 77 Check the SS1 circuit connections against the circuit diagram 2. No safety faults and alarms. 3. Run the drive. 4. Ensure that the correct drive is running. 5. Select SS1 while the drive is running. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 77...
  • Page 78 Ensure that error 70, Int fail speed limit SLSa : Reaction STO is shown. 7. Deselect SLS. 8. Check the following: • Safety Func. Pending is shown. • SLS is deselected and inactive. 9. Restart the drive and check that the motor runs normally. 78 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 79 Safe Func. Pending is shown. 15. Reset the drive and check that the motor runs normally. 16. Ensure that the SLS function is ready to operate. 17. Document and sign the commissioning report. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 79...
  • Page 80 Installation Guide | VLT® Safety Option MCB 150/151 Service and Repair Tester/Approver Date: Signature: 80 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 81: Warnings And Alarms

    The following is shown in online mode in the MCT 10 Set-up Software: • Status of the safety option input and output errors, messages, and the corresponding remedies are shown in the expanded diagnosis system of the MCT 10 Set-up Software. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 81...
  • Page 82: Warnings And Alarms

    Int Fail tolerance error ex- dynamic of feedback filter ceeded: Reaction STO to (parameter 42-15 Feedback occur. Filter). • Otherwise increase pa- • Load change takes place rameter 42-45 Delta V. during ramping. 82 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 83 Second, try to make a general reset of the safety option with the Administration but- ton (safety option goes back to blank initial state). • If the problem persists, contact Danfoss. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 83...
  • Page 84 MCT 10 safe plug-in or by CRC se- con- CRC mis- does not match lect/LCP copy stant match: Reac- the stored CRC tion STO value on the drive. 84 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 85 • If the problem per- sists, contact Dan- foss. Internal failure • First, power cycle Red con- safety option the drive. stant • If the problem per- sists, contact Dan- foss. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 85...
  • Page 86 • If the problem persists, contact Danfoss. Internal fail- • First, power cycle the Red con- ure safety op- drive. stant tion • If the problem persists, contact Danfoss. 86 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 87 42-21 Type is set assigned to DI2. legal signal correctly or the con- 500 ms, off level. nected sensor is in- 500 ms) stalled according to • Sensor is the specification. broken. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 87...
  • Page 88 Int fail speed See 70 See 70 Red con- limit SLSa: Re- stant action SS1a Int fail speed See 70 See 70 Red con- limit SLSb: Re- stant action SS1a 88 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 89: Safety Option Warning

    A warning message notifies that an issue exists on the safety option. It is not handled as an internal or external failure. These messages are defined to indicate that a manual user action is required. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 89...
  • Page 90: Safety Option Reset Message

    PUST and when a safety function gets released and is configured to be confirmed that the S tatus !1(1) motor is able to run. 0 R PM None 0.00 KW SafeOpt. initialised !Safe S top [W68] 90 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 91 Speed monitoring suspension warning has occurred. Warning cause: Suspension of speed moni- toring for certain duration. S tatus !1(1) 0 R PM None 0.00 KW SO Suspend-SpeedMon !Safe S top [W68] Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 91...
  • Page 92: Technical Specifications

    (328 ft) shielded motor cable, no load on motor) 9.2.3 HTL Encoder Input (VLT® Safety Option MCB 151) Number of encoder inputs 2 (2 x single ended inputs A; B) Encoder types HTL incremental encoders, HTL proximity sensor 92 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 93: Outputs

    <30 m (98.4 ft) (shielded or unshielded cable), >30 m (98.4 ft) (shielded cable) 9.4.2 Cable Cross-sections Digital inputs/output supply voltage 0.75 mm /18 AWG, AEH without plastic collar in accordance with DIN 46228/1 Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 93...
  • Page 94: Reset Characteristics

    Low Voltage Directive (2006/95/EC) EN 50178 EN 61800-5-1 Table 35: Safety Standards Name of standard Number/description Safety of Machinery EN ISO 13849-1 IEC 62061 IEC 60204-1 Functional Safety IEC 61508-1 to -7 IEC 61800-5-2 94 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 95 PL d (cat 3) Mean time to dangerous failure of each channel MTTFd: 245 years (High) Average diagnostic coverage : 86% (Low) Safe failure fraction SFF: 90% Proof test interval 20 years Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 95...
  • Page 96: Appendix

    Safely limited speed. Safety option. SRECS Safety-related electrical control system (IEC 62061). SRP/CS Safety-related part of control systems (EN ISO 13849-1). Safe stop 1. Safe Torque Off. Mission time (EN ISO 13849-1). 96 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 97: Conventions

    Parameter name. Parameter option. Parameter group name. • All dimensions in drawings are in metric values (imperial values in brackets). • An asterisk (*) indicates the default setting of a parameter. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 97...
  • Page 98 33, 34, 94 Error response 29, 31 Risk assessment RS485 45, 52, 57, 70 Feedback source 55, 87 S-ramp High-demand mode Safe jog Safe motion monitoring HTL encoder 20, 35, 44 Safe output 98 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 99 SS1 ramp Status indicator 19, 81 20, 28, 31, 32 Supply voltage 19, 44 Symbols Test Test pulse pattern Thermal protection TTL encoder 20, 35, 44 UL certification 53, 57, 70 Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 99...
  • Page 100 Safe state If a safe state fault is detected, the safety option goes into safe state. This includes faults related to integrity of hardware and firmware. 100 | Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292...
  • Page 101 If the term is used outside the context of safety instructions, a warning alerts to a potential problem that was detected by a monitoring function. A warning is not an error and does not cause a transition of the operating state. Danfoss A/S © 2018.09 AQ279747441421en-000101 / 130R0292 | 101...
  • Page 102 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies.