■Definition and terminology

Term
A
Analog current output
Analog output function
Analog voltage output
Auto-preset
Auto-shift
B
Bottom value display (mode)
C
Chattering
Chattering prevention function
Copy function
D
Delay time
digit (Min. setting unit)
Digital filter
Display accuracy
Display color
Display resolving power
Display value fine adjustment
(function)
Refer to "Analog output (function)".
Function to output the voltage or current in proportion to the pressure.
Refer to "Analog output (function)".
Performs pressure setting automatically by detecting the increase and
decrease in pressure. For example, if this function is used for a suction test,
the pressure setting will be completed by performing suction and release of
the workpiece.
A function to correct the set value of the switch output in accordance with the
applied pressure in case the switch operation is unstable due to pulsation of
applied pressure. This function is used in applications such as vacuum
adsorption. The pressure when a signal is externally input is set as a
reference value with which the pressure that turns the switch on or off can be
shifted.
Shows the minimum pressure from when the power was supplied to the
current time.
The problem of the switch output turning ON and OFF repeatedly around the
set value at high frequency due to the effect of pulsation.
A function to delay the response time of switch output in order to prevent
chattering.
A function to copy a pressure setting value and function setting (Excludes
finely adjusted displayed values and line names.).
The setting time from when the pressure applied to the pressure switch
reaches the set value, to when the ON-OFF output actually begins working.
Delay time setting can prevent the output from chattering.
The response time indicates when the set value is 90% in relation to the step
input.
Shows how precisely the pressure can be displayed or set by the digital
pressure switch. When 1 digit = 1 kPa, the pressure is displayed in increments
of 1 kPa, e.g., 1, 2, 3, ..., 99, 100.
Function to add digital filtering to the fluctuation of pressure value. Smooth the
fluctuation of displayed value for sharp start up or fall of the pressure.
When the function is valid, digital filtering is reflected to the ON/OFF of the
switch output.
Output chattering or flicker in the measurement mode display can be reduced
by setting the digital filter.
Shows The maximum deviation between the displayed pressure value and
the true pressure.
Indicates the color of the number of digital display. Always green, always red,
green (switch OFF)  red (switch ON), red (switch OFF)  green (switch
ON) are available.
Indicate in how many the rated pressure range can be divided to display.
(Example: When the value can be displayed down to 0.001 MPa for the
product for 0 to 1 Mpa, the resolution is 1/1000)
Displayed pressure value can be adjusted within the range of 5%R.D. (5%
of displayed value). It is used if the true pressure value is known, or to
eliminate differences between the displayed values of different instruments
that are measuring the same pressure.
-11-
Definition
No.PS※※-OMU0006-A