■[F 5] FUNC terminal setting
When the product with analog output/auto shift input function is used, the FUNC terminal setting can be
selected.
Analog output: Outputs proportional output according to the applied pressure.
Auto-shift: The display indicates the change of relative flow from the reference value.
Auto-shift zero: The display is set to zero when the signal is input, and therefore the display indicates the
change of relative flow from the reference value.
Copy input: Copies the set value. Refer to "[F97] Selection of copy function" on page 56.
<Operation>
Press the
or
FUNC terminal setting
Press the
or
[AoUt] (Analog
output) is
selected
Press the
button to set.
Return to
function
selection mode.
button in function selection mode to display [F 5].
Press the
button.
button to select the FUNC terminal function.
[ASin] (Auto-shift
input) is selected
Press the
button to set.
Setting of auto-shift
function
Press the
or
button to select the
auto-shift function.
Press the
button to set.
-39-
Move on to FUNC terminal setting.
Move on to setting of
auto-shift function.
Move on to setting of
effective output.
[CoPY] (Copy
input) is
selected
Press the
button to set.
Return to
function
selection mode.