Genie GTH-2506 Service Manual page 106

Hide thumbs Also See for GTH-2506:
Table of Contents

Advertisement

Section 6 • Fault Codes
FAULT CODES
SPN
FMI
Short Text Detail
523921
1
Physical range check low for burner temperature
105
3
Sensor error charged air temperature; signal range check high
105
4
Sensor error charged air temperature; signal range check low
105
0
High charged air cooler temperature; warning threshold exceeded
105
0
High charged air cooler temperature; shut off threshold exceeded
412
3
Sensor error EGR cooler downstream temperature; signal range check high
412
4
Sensor error EGR cooler downstream temperature; signal range check low
523960
0
Physical range check high for EGR cooler downstream temperature
523960
1
Physical range check low for EGR cooler downstream temperature
51
6
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check high
51
5
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check low
51
7
Actuator position for EGR-Valve (2.9,3.6) or Throttle-Valve (6.1,7.8) not plausible
51
5
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); open load
51
12
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); powerstage over temperature
51
3
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to battery
51
4
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); short circuit to ground
51
12
Mechanical actuator defect EGR-Valve (2.9,3.6) or Throttle-Valve (6.1,7.8)
51
6
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check high
51
5
Actuator error EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check low
51
3
Position sensor error of actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check high
51
4
Position sensor error actuator EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8); signal range check low
4769
2
Sensor exhaust gas temperature downstream (DOC); plausibility error
4766
0
Physical range check high for exhaust gas temperature downstream (DOC)
4766
1
Physical range check low for exhaust gas temperature downstream (DOC)
4769
3
Sensor error exhaust gas temperature downstream (DOC); signal range check high
4769
4
Sensor error exhaust gas temperature downstream (DOC); signal range check low
4768
2
Sensor exhaust gas temperature upstream (DOC); plausibility error
4765
0
Physical range check high for exhaust gas temperature upstream (DOC)
4765
1
Physical range check low for exhaust gas temperature upstream (DOC)
4768
3
Sensor error exhaust gas temperature upstream (DOC); signal range check high
4768
4
Sensor error exhaust gas temperature upstream (DOC); signal range check low
3248
4
Sensor error particle filter downstream temperature; signal range check low
1180
11
Sensor exhaust gas temperature upstream turbine; plausibility error
1180
3
Sensor error exhaust gas temperature upstream turbine; signal range check high
6-14
GTH-2506 GTH-3007
August 2018
Part No. 57.4400.9220GT

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gth-3007

Table of Contents