Smart Fiber Amplifier
E3NX-FA
AN
□□

INSTRUCTION SHEET

Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
* 3 1 1 6 8 2 6 - 5 A 1 *
©
OMRON Corporation 2017 All Rights Reserved.
Indicates a potentially hazardous situation which, if not avoided,
WARNING
will result in minor or moderate injury, or may result in serious
injury or death.Additionally there may be significant property damage.
Warning Indications
WARNING
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR SAFE USE
The following precautions must be observed to ensure safe operation of the product. Doing so may cause
damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
· To secure the safety of operation and maintenance, do not install the product close to high-voltage
devices and power devices.
· High-Voltage lines and power lines must be wired separately from this product. Wiring them together or
placing them in the same duct may cause induction, resulting in malfunction or damage.
· Do not apply any load exceeding the ratings. Otherwise damage or fire may result.
· Do not short the load. Otherwise damage or fire may result.
· Connect the load correctly.
· Do not miswire such as the polarity of the power supply.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such as
the ambient temperature and the power supply voltage. Attention must be paid during operation or cleaning.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
· Do not use the Sensor in water, rainfall, or outdoors.
· Use the product in the IP54 enclosure.
· UL Standard Certification
Only the sensors with Enhanced UL Certification Mark are certified by UL. They are intended to be
supplied by a "Class 2 circuit". When used in United States and Canada, Please use the same Class 2
source for input and output.The overcurrent protection current rating is 2A max. They were evaluated as
Open type and shall be installed within a enclosure.
PRECAUTIONS FOR CORRECT USE
· Be sure to mount the unit to the DIN track until it clicks.
· When using a connector type product, place a protective label (provided with the E3X-CN series) on the
power supply connecting terminals that are not used, to prevent electric shock or short circuit.
Protective Label
Power Supply Connecting Terminal
· The length for the cable extension must be 30 m or less (or less than 10 m for S-mark certified models).Be sure to use a
cable of at least 0.3 mm
for extension.The power voltage must be 24 to 30 V when connecting amplifier units with
2
extension cable and wire-saving connector.
· Do not apply the forces on the cord exceeding the following limits:
Pull: 40N; torque: 0.1N·m; pressure: 20N; bending: 29.4N
· Do not apply excessive force such as tension, compression or torsion to the amplifier unit with the fiber unit fixed to
the amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after the power is
turned on depending on use environment.
· The product is ready to operate 200 ms after the power supply is turned ON.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work properly, resulting
in malfunction of the unit. In such case, increase the threshold.
· The Communication Unit E3X-DRT21-S, E3X-CRT, E3X-ECT and E3NW cannot be connected.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop
using the product, turn off the power, and consult your dealer.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
Checking the Package Content
• Amplifier Unit: 1
• Instruction Sheet (this sheet): 1 (Japanese, English, Chinese and Korean )
1

Installation

Dimensions
1-1
21.7
27.1
10
5.1
147.1
(Max. with the protective cover open)
With an thin-diameter fiber
attachment (E39-F9)
16.5
20.5
(9.4)
16
OPTICAL COMMUNICATION
4.8
POSITION
(37.9)
(20.5)
(2/4)
71.8
Mounting bracket E39-L143 (sold separately)
<Pre-wired Type>
Dimensions in parentheses () indicates the ones with related components.
The cover could come off if it is tilted by 170 degrees or more.

Input/Output Circuit Diagram

1-2
■E3NX-FA11AN (NPN)
■E3NX-FA41AN (PNP)
10 to 30 VDC
Brown
Black:
Control Output
Orange
Analog Output
10kΩ min.
0V
Blue

Mounting the Amplifier Unit

1-3
Mounting on DIN Track
(1)
Let the hook on the Amplifier Unit's Fiber Unit
connection side catch the track.
Push the unit until the hook clicks into place.
(2)
DIN track (PFP-□N) is sold separately.
Removing from DIN Track
(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while performing step (1).
Joining Amplifier Units
Mount the Amplifier Units one at a time onto the DIN track.
(1)
(2)
When using a wire-saving connector, mount the master
connector to A and slave connector to B.
(3)
Slide the Amplifier Unit until the Amplifier Unit is closely
attached.(Arrow 3) (For the wire-saving connector type, be
sure that a master connector and a slave connector, or a slave
connector and a slave connector are connected.)
(4)
Use End Plates (PFP-M: separately sold) at the both ends
of the grouped Amplifier Units to prevent them from
separating due to vibration or other cause.(Arrow 4)
Tighten the screw on the End Plates using a driver.(Arrow 5)
(5)
Up to 30 Amplifier Units can be joined.
Under
environments such as vibration, use an End Plate even
with a single amplifier unit. If mounting the product
without joining the amplifier unit, seal the side optical
communication part with lightproof tape.
Mounting Fiber Unit
1-4
Use Fiber Cutter
2
(1) Insert a Fiber Unit into a fiber cutter hole.
(2) Press down the blade at a single stroke to cut the
Fiber Unit.
Mount Fiber Unit
Standard Fiber Unit
(1) Open the cover.
Hole (dia. 2.2 mm) x 3
(2) Raise the lock lever.(Release)
(3) Insert the Fiber Unit in the fiber unit hole to the
bottom.
(4) Return the lock lever to the original position and fix
the Fiber Unit.(Lock)
・To mount the thin-diameter Fiber Unit, an attachment
(E39-F9) is required.(The attachment is included with
the applicable Fiber Unit.)
When mounting a coaxial reflective Fiber Unit, insert the
single-core Fiber Unit to the upper hole (Emitter side) and the
Single Core
multi-core Fiber Unit to the lower hole (Receiver side).
Multi Core
2

Settings

Setting and Display Overview
2-1
Unit: mm
[L/D Indicator : Orange]
Displays Light ON/Dark ON setting.
[DPC Indicator : Green]
Turns ON when Dynamic Power Control is
effective.
[ST Indicator : Blue]
[OUT Indicator:Orange]
Lit up when the smart tuning function is effective. Put out
when the detection function is changed or the settings are
Turns ON when Output is ON.
initialized.
Threshold Level
Incident Light
Level
Green Digital
Display
White Digital
Display
Sensitivity Setting
Minute Threshold
Adjustment
S.TUNE
Button
【    】
[UP/DOWN] Button
Performs tuning and [ST Indicator]
The green digital value
turns ON.
changes.
Smart Tuning [Easy Sensitivity Setting]
2-3
①Detecting Presence/Absence of Workpiece
● 2-point Tuning
Workpiece is present
10 to 30 VDC
Brown
②Increasing Resistance to Dust and Dirt
Black:
Control Output
● Maximum Sensitivity Tuning
Orange
Analog Output
Through-beam:
Reflective:
10kΩ
Workpi e ce i s present
Workpiece is absent
min.
0V
Workpiece
Blue
③Making Adjustment with Moving Workpiece without Stopping the Line
● Full Auto Tuning
Fiber Unit Connection Side Hook
④Determining the Workpiece Position
2
1
● Position Tuning
Workpiece
is absent
DIN Track
A
3
B
⑤Detecting a Transparent or Microscopic Object (Setting a Threshold with Received Light Intensity Ratio)
● Percentage Tuning
5
Percentage tuning setting
4
ON
Refer to " Detailed Settings".
Tighten the screw
while pressing the End Plate.
⑥Restoring the Received Light Intensity Weakened due to Dust or Dirt / Restoring the Saturated Received Light Intensity
● Power Tuning
Workpiece is absent
Fiber Cutter E39-F4
● Smart Tuning Error
(Provided with
the Fiber Unit)
Error / Display
Cause
Thin-diameter
Near Error
The light level difference
Fiber Unit Hole x 2
between Points 1 and 2 are
err
Thin-diameter Fiber
extremely small.
1
Attachment: E39-F9
Over Error
Incident light level is too high.
err
Lock Lever
Lock
Low Error
Incident light level is too low.
Release
Cover
4
err
2
1
3
Fiber Unit
Output switching
2-2
+ : Press both
Press
button.
Setting Reset
L/D
L/D
Through-beam: Set to "Dark ON" to turn the
Key Lock
output ON with a workpiece in the detection area.
UP/DOWN
MODE
Zero Reset
[L/D Indicator] turns   ON.
UP
Solution Viewer
MODE
L/D
Reflective: Set to "Light ON" to turn the
Refer to "
Convenient
output ON with a workpiece in the detection area.
Setting Features".
[L/D Indicator] turns
Mode/OUT Switch
Output Switch
[L/D] Button
[MODE]Button
Switches between SET mode and RUN mode by a
A single press switches between
long press (3 seconds or longer) of the key. If pressed
Light ON/Dark ON. [L/D] Indicator
changes.
and held for 1 second, OUT is switched (2 outputs).
Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.
Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.
9999
1pnt
Workpiece is absent
Moving the finger off the button displays "2Pnt".
Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.
Threshold setting: Set the light intensity of approximately 7% when the button pressed.
0
1pnt
Hold for 3 seconds or longer
Release the button when "FULL" appears.
Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.
Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.
9999
Hold for 7 seconds or longer
Workpiece
Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.
Threshold setting: Set to the same value as the received light amount Desirable detection position.
Desirable
detection
9999
1pnt
position
Moving the finger off the button displays "2Pnt".
Received light intensity setting: Adjusts the light intensity level without the presence of a sensing object to the power tuning level.
Threshold setting: Set to (Light intensity level that has been set according to the setting above x Percentage tuning level).
1500
per
Workpiece is absent
Hold for 1 seconds or longer
Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.
Threshold setting: Not changed.
1500
Hold both for 1 sec. or longer
Minute Adjustment of Threshold Level
2-4
Remedy
・Change the detection function to the mode of slower response time.
・Narrow the distance between emitter and receiver. (Though-beam model)
・Move the Fiber Head closer to the sensing object. (Reflection model)
Press
・Widen the distance between emitter and receiver. (Though-beam model)
・Move the Fiber Head away from the sensing object. (Reflection model)
UP/DOWN
the threshold level.
・Use a thin-diameter Fiber.
・Make the distance between emitter and receiver closer. (Through-beam model)
Hold the key for high-speed level
・Move the Fiber Head closer to the sensing object. (Reflection model)
adjustment.
Workpiece
Workpiece
ON.
Execution can be done even if the order of workpiece
exists/not exist is reversed.
2500
2pnt
Setting is Completed
It will become susceptible to the influence of
background objects.
0
Setting is Completed
1500
Release the button when the workpiece passed through.
Setting is Completed
9999
Hold for 3 seconds or longer
Setting is Completed
When percent tuning setting is ON, only power tuning can be performed.
Other tunings cannot be performed.
Setting is Completed
Adjustment for a reflective type requires the presence of a workpiece.
Both thru-beam and reflective types require the presence of a workpiece
if the setting is made after position tuning.
Setting is Completed
The threshold level
The threshold level
button to adjust
becomes higher.
becomes lower.
E3NX-FA
AN
□□