Omron E3NC-LA0 Instruction Sheet

Smart laser amplifier

Advertisement

Quick Links

Smart Laser Amplifier
E3NC-LA0
INSTRUCTION SHEET
Thank you for selecting an OMRON product. This sheet
primarily describes precautions
required in installing and operating the product.
• A specialist who has the knowledge of electricity must treat
the product.
• Please read this manual carefully, and use it correctly after
thoroughly understanding the product.
• Please keep this manual properly for future reference
whenever it is necessary.
* 4 0 1 3 2 9 8 - 2 C *
©
OMRON Corporation 2013 All Rights Reserved.
PRECAUTIONS ON SAFETY
Meanings of Signal Words
Indicates a potentially hazardous situation which, if not avoided,
WARNING
may result in minor or moderate injury or in property damage.
Warning Indications
WARNING
This product is not designed or rated for ensuring safety of persons
either directly or indirectly. Do not use it for such purpose.
Do not use the product with voltage in excess of the rated voltage.
Excess voltage may result in malfunction or fire.
Never use the product with an AC power supply. Otherwise,
explosion may result.
PRECAUTIONS FOR SAFE USE
The following precautions must be observed to ensure safe operation of the product. Doing so may cause
damage or fire.
· Do not install the product in the following locations.
(1) Locations subject to direct sunlight
(2) Locations subject to condensation due to high humidity
(3) Locations subject to corrosive gas
(4) Locations subject to vibration or mechanical shocks exceeding the rated values
(5) Locations subject to exposure to water, oil, chemicals
(6) Locations subject to steam
(7) Locations subjected to strong magnetic field or electric field
· Do not use the product in environments subject to flammable or explosive gases.
· Do not use the product in any atmosphere or environment that exceeds the ratings.
· To secure the safety of operation and maintenance, do not install the product close to high-voltage
devices and power devices.
· Do not use the product if the case is damaged.
· Burn injury may occur. The product surface temperature rises depending on application conditions, such
as the ambient temperature and the power supply voltage. Use caution when operating or cleaning the
product.
· When setting the sensor, be sure to check safety such as by stopping the equipment.
· Be sure to turn off the power supply before connecting or disconnecting wires.
· Do not attempt to disassemble, repair, or modify the product in any way.
· When disposing of the product, treat it as industrial waste.
PRECAUTIONS FOR CORRECT USE
· Do not miswire such as the polarity of the power supply.
· Be sure to mount the unit to the DIN track until it clicks.
· To prevent electric shock or short circuit, put a protection cap on unused connection power supply
terminals.
Protective Cap
· Do not apply excessive force (9.8N max.) such as tension, compression or torsion to the connector of the
sensor head that is fixed to the amplifier unit.
· Always keep the protective cover in place when using the product. Not doing so may cause malfunction.
· It may take time until the received light intensity and measured value become stable immediately after
the power is turned on depending on use environment.
· The product is ready to operate 200 ms after the power supply is turned ON.
· The Mobile Console E3X-MC11, E3X-MC11-SV2 and E3X-MC11-S cannot be connected.
· The mutual interference prevention function does not work when in combination with E3C/E2C/E3X.
· If the unit receives excessive sensor light, the mutual interference prevention function may not work
properly, resulting in malfunction of the unit. In such case, increase the threshold.
· Sensor communication unit E3NW can be used. E3X-DRT21-S and E3X-CRT/ECT cannot be used.
· If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke,
immediately stop using the product, turn off the power, and consult your dealer.
· Do not use thinner, benzine, acetone, and lamp oil for cleaning.
Checking the Package Content
• Amplifier Unit: 1
• Instruction Sheet (this sheet): 1 (Japanese, English and Chinese)
Compatible Communication Unit (Sold Separately)
E3NW Series Communication Unit, Distribution unit E3NW-DS
1
Installation
Dimensions
1-1
30.2
27.8
13.8
11.5
10
2.6
(2/3)
3.9
5
32.1
9.4
16
49.5
39.5
102.4
DIN Track
SOLD SEPARATELY
PFP-□-N
Dimensions in parentheses () indicates the ones with related components.
The cover could come off if it is tilted by 152 degrees or more.
Mounting the Ampli er Unit
1-2
Mounting on DIN Track
(1)
Let the hook on the Amplifier Unit's Sensor Head
  connection side catch the track.
(2)
Push the unit until the hook clicks into place.
Fiber Unit Connection Side Hook
Removing from DIN Track
2
(1) Push the unit in the direction 1.
(2) Lift the unit in the direction of arrow 2 while
  performing step (1).
Joining Ampli er Units
(1)
Mount the Amplifier Units one at a time onto the DIN track.
Slide the Amplifier Unit until the communication connector is
closely attached.(Arrow 3)
(2)
Use End Plates (PFP-M: separately sold) at the both
ends of the grouped Amplifier Units to prevent them from
separating due to vibration or other cause.(Arrow 4)
(3)
Tighten the screw on the End Plates using a driver.(Arrow 5)
Tighten the screw while pressing the End Plate.
Up to 30 Amplifier Units can be connected to
E3NW Series Communication Unit.
Under environments such as vibration, use an End Plate
even with a single amplifier unit.
Mounting the sensor head
1-3
1.
Open the protection cover.
2.
Insert the sensor head, with the lock lever on
its connector area facing upward, all the way
2
into the connector port.
The color of the connector cover for E3NC-LH
is blue.
Make sure to avoid misconnection by
confirming the cover color in advance.
To remove it, press and hold the lock lever
Lock Lever
then pull the sensor head out.
Connector cover: Blue
Fix the sensor head with M3 screws.
Apply tightening torque of 0.5N・m for fixing.
・Do not touch the emitter and receiver
areas of the sensor head.
 A fingerprint may prevent proper
measurement.
 If you accidentally touch it, use a soft
cloth to wipe it out.
・Fix the connector area so that it should
not be affected by oscillation and
impact.
2
Settings
For settings with the Communication Unit,
refer to the User's Manual that comes with the Communication Unit.
Setting and Display Overview
2-1
[L/D Indicator : Orange]
[OUT Selection Indicators:Orange]
Displays Light ON/Dark ON setting.
[DPC Indicator : Green]
Turns ON when Dynamic Power Control is
effective.
[ST Indicator : Blue]
[OUT Indicator:Orange]
Turns ON when Smart Tuning is in progress.
Turns ON when Output is ON.
Incident Light
Threshold Level
Green Digital Display
Level
White Digital
Sensitivity Setting
Minute Threshold
Adjustment
S.TUNE
【    】
Button
[UP/DOWN] Button
Performs tuning and [ST Indicator]
The green digital value
turns ON.
changes.
Smart Tuning [Easy Sensitivity Setting]
2-4
Basic Setting
OPTICAL COMMUNICATION
POSITION
● 2-point Tuning
Unit: mm
Workpiece is present
Enhancing Durability of the Head against Dust and Stain
● Maximum Sensitivity Tuning
Workpiece is absent
1
Tuning with regressive reflection is not recommended as the variation of the light values may occur, resulting in malfunction of the product.
Setting for a Moving Workpiece
● Full Auto Tuning
DIN Track
3
Setting to Detect by Workpiece Position
4
5
● Position Tuning
Workpiece
is absent
Detecting a Transparent or Microscopic Object
● Percentage Tuning
Percentage tuning setting
ON
Refer to " Detailed Settings".
Initializing Light Intensity Changed Due to Dust or Dirt
1
● Power Tuning
Workpiece
Output switching
2-5
■OUT Selection Indicator switches to switch the settings.
1.
Push short the [MODE] button in [Measurement Mode].
2.
OUT Selection Indicators (Output 1/Output 2) switch.
[Output 1]
OUT Selection Indicator (Output 1)
[Output 2]
OUT Selection Indicator (Output 2)
L/D switching can be performed on Output 2 as well.(Refer to 2-2)
Switching Control Output
2-2
Press
button.
+ : Press both
L/D
Set to "Light ON" to turn the output ON with a workpiece in the detection area.
Setting Reset
[L/D Indicator] turns
L/D
Set to "Dark ON" to turn ON the output without a sensing object.
Key Lock
[L/D Indicator] turns
UP/DOWN
MODE
Zero Reset
Sensor Head Display
2-3
UP
Solution Viewer
MODE
L/D
Refer to "
Convenient
[OUT Indicator:Orange]
Setting Features".
Turns ON when Output is ON.
Mode/OUT Switch
Output Switch
[STABILITY Indicator: Green]
[MODE]Button
[L/D] Button
Turns ON when output is stable.
Switches between SET mode and RUN mode by a
A single press switches between
*
Setting to the stable area makes the operation more reliable against the
long press (3 seconds or longer) of the key. If Push
Light ON/Dark ON. [L/D] Indicator
environmental changes (temperature, voltage, dust, setting deviation) after
installation. Be careful on environmental changes when using the sensor in an
short, OUT is switched.
changes.
application in which stable area cannot be obtained.
Received light intensity setting: Adjust to the either higher value of Point 1 and Point 2 power tuning levels.
Threshold setting: Set to the middle between Point 1 and Point 2 received light intensity values.
9999
1pnt
Workpiece is absent
Moving the finger off the button displays "2Pnt".
Received light intensity setting: Adjust the received light amount to "0" when the button is pressed.
Threshold setting: Set the light intensity of approximately 7% when the button is pressed.
0
1pnt
Hold for 3 seconds or longer
Received light intensity setting: Adjust the power tuning level to the maximum received light amount when the button is pressed.
Threshold setting: Set to the middle between the maximum and minimum received light amount values when the button is pressed.
9999
Workpiece
Hold for 7 seconds or longer
Receiving light setting: Adjusts the receiving light amount to a half of that for the power tuning level with Desirable detection position.
Threshold setting: Set to the same value as the received light amount Desirable detection position.
Desirable
detection
9999
1pnt
position
Moving the finger off the button displays "2Pnt".
Received light intensity setting: Adjust it to the received light intensity or power tuning level without detection object.
Threshold setting: Light amount without a workpiece x (1 + Percentage tuning level)
Workpiece is absent
1500
per
Hold for 1 seconds or longer
Received light intensity setting: Adjust the power tuning level to the received light amount when the button is pressed.
Threshold setting: Not changed.
9999
Hold both for 1 sec. or longer
Smart Tuning Error
Error / Display / Cause
Near Error
err
The light level difference
between Points 1 and 2 are
extremely small.
Over Error
err
Incident light level is too
high.
Low Error
err
Incident light level is too low.
Push short the [MODE] button in [Measurement Mode].
Minute Adjustment of Threshold Level
2-6
Press
UP/DOWN
the threshold level.
Hold the key for high-speed
level adjustment.
Workpiece
ON.
Output
ON
for Light-on
OFF
Output
ON
ON.
for Dark-on
OFF
Stable indication
Operation indication (Orange)
L • ON
D • ON
(Green)
*
Stable
ON
operation
ON
OFF
area
Operation
*
level x1.1
OFF
Unstable
Operation
operation
level
area
*
Operation
OFF
ON
level x0.9
Stable
ON
operation
area
Execution can be done even if the order of workpiece
exists/not exist is reversed.
2500
2pnt
Setting is Completed
It will become susceptible to the influence of
background objects.
0
Release the button when "FULL" appears.
Setting is Completed
1500
Release the button when the workpiece passed through.
Setting is Completed
5000
Hold for 3 seconds or longer
Setting is Completed
When percent tuning setting is ON, only power tuning
can be performed. Other tunings cannot be performed.
Setting is Completed
Diffuse reflection: Perform tuning with the presence of a
sensing object.
Regressive reflection: Perform tuning without the
presence of a sensing object.
After positioning tuning performed, a sensing object must
be present for both diffuse and regressive reflections.
Setting is Completed
Error Origin Tuning Type
Remedy
・Change the detection function to the mode of slower response time.
2-point Tuning
・Move the Sensor Head closer to the sensing object.
Full Auto Tuning
Positioning Tuning
・ Move the Sensor Head away from the sensing object.
All
・ Move the Sensor Head closer to the sensing object.
Other than maximum
sensitivity tuning
The threshold level
The threshold level
button to adjust
becomes higher.
becomes lower.
E3NC-LA0

Advertisement

loading

Summary of Contents for Omron E3NC-LA0

  • Page 1 [DPC Indicator : Green] 13.8 Setting Reset [L/D Indicator] turns Turns ON when Dynamic Power Control is Thank you for selecting an OMRON product. This sheet Output 11.5 effective. primarily describes precautions Set to "Dark ON" to turn ON the output without a sensing object.
  • Page 2 0 Note: The mutual interference prevention functions are disabled if the SHS mode is selected for detection function. Power Tuning ON/OFF Setting   To Turn ON/OFF the Light Amount Adjustment at Tuning Buyer’s application or use of the Product. At Buyer’s request, Omron will Refer to "1-2 Mounting Amplifier Unit" units for mutual High-speed mode (HS)