JRC JMA-933B Installation Manual page 48

Chart radar
Table of Contents

Advertisement

2) Preventing the connecttng portion from becoming detahed due to
vibration
Keep the connecting portion between the coaxial cable and the flexible
waveguide and the scanner's chassis, and provide supporting members, as
shown in Fig 2-12 and Fig 2-13, to prevent the connecting portion from
becoming detached due to vibration.
The distance from the connecting portion and the supporting member should
be 400 millimeters for the S-band and 300 millimeters for X-band.
If the distance from the connecting portion and the supporting member is
longer than the above distance, vibration may cause metal fatigue, resulting in
the occurrence of malfunction even if the connecting portion is not removed.
Fig 2-9 Positon of S-band supporting member
* For the cable end processing , refer to the procedure manual which comes with the
cable.
Fig 2-10 Position of X-band supporting member
2-40
Scanner terminal
Waveguide Clamp