Installation Of Power Control Unit; Connection With Nke-1125,Ntg-3225,Nke-1130,Ntg-3230 - JRC JMA-933B Installation Manual

Chart radar
Table of Contents

Advertisement

6.2

INSTALLATION of POWER CONTROL UNIT

Power control unit NQE-3167 is used when an antenna and a transmitter-receiver are installed at al
location away from the briges, such as aforemast.
By using NQE-3167 power control unit, the maximum length of the cable that connects between the
display unit and the antenna (transmitter-recever) can be extended up to 400 meters.
2Unit:
3Unit:
(When power control unit (NQE-3167)is used)
2Unit:
3Unit:

6.2.1 Connection with NKE-1125,NTG-3225,NKE-1130,NTG-3230

Use 14-core composite cable 2695110056 for the installation of those types of antennas.
For the procedures for processing the cable end, see Fig 5-14: Equipment cable end processing.
For the wiring procedures, see Section 6.2.8 Inter-board connection diagram of power control unit.
Maximum length of the cable connecting between the 65m
Display Unit and the Scanner Unit
Maximum length of the cable connecting between the 30m
Antenna and the transmitter-receiver:
Maximum length of the cable connecting between the 35m
Transmitter-receiver and the display unit:
Maximum length of the cable connecting between the 400m
Display unit and antenna (transmitter-receiver):
Maximum length of the cable connecting between the 65m
Power control unit and the scanner Unit
Maximum length of the cable connecting between the 30m
Scanner Unit and the transmitter-receiver:
Maximum length of the cable connecting between the 35m
Transmitter-receiver and the power control unit:
6-13