1.1 Functional Description (cont.)

Electronic Ignition Configuration

In units configured for electronic ignition, an ignition module connected to an ignitor assembly
replaces the pilot system. The ignition module performs four important functions: it provides fuse
protection for the 24-volt circuit, provides an ignition spark, supplies voltage to the gas valve, and
proofs the pilot flame.
The module contains a 4-second time delay circuit and a coil that activates the gas valve. The
ignitor assembly consists of a spark plug, a pilot, and a flame sensor element.
At start-up the ON/OFF switch is placed in the "ON" position, supplying 12 VDC to the heat control
circuitry in the controller or computer and to one side of the heat relay coil on the interface board. If
resistance in the temperature probe indicates the temperature in the frypot is below 180°F (82°C),
the current flows through a melt cycle circuit where a timer switch alternately closes for 3 seconds
and opens for 24 seconds. If the temperature is 180°F (82°C) or above, the current flows through a
heat circuit, bypassing the timer switch. In either case, current is supplied to the other leg of the heat
relay coil which then closes an electronic switch in the 24 VAC circuit to provide current to the
ignition module.
Circuitry in the ignition module sends 24 VAC current to the gas valve via a normally closed high-
limit switch and a drain safety switch. Simultaneously, the module causes the ignitor to spark for 4
seconds to light the pilot flame. A flame sensor verifies that the pilot is lit by measuring the flow of
microamps through the flame. If the pilot does not light (or is extinguished), current to the ignition
module is cut, preventing the main valve from opening, and the ignition module "locks out" until the
power switch is turned "OFF", then back "ON".
47 SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
Inside the Ignition Module
Out to
Gas Valve
To Alarm
25 V +
25 V GND
Ignition Wire
1-2
Coil
TD
HV
Flame Sensor