Connecting the 34401A to a PC using Agilent Connection Expert
Agilent Connection Expert (ACE) is an Agilent IO Libraries utility that configures the IO interface between the 34401A
and your PC. The IO Libraries are contained on the Agilent Automation-Ready CD or may be downloaded from the
Agilent Developer Network website at: http://adn.tm.agilent.com.
1. Install the Agilent IO Libraries on your PC and connect a GPIB cable between the PC and the 34401A.
2. From the PC taskbar, click the Agilent IO Control icon
and select 'Agilent Connection Expert' from the menu.
3. Select the PC's GPIB interface and select 'Add Instrument'
from the Connection Expert menu bar.
4. Select the GPIB0 interface and then select the
34401A GPIB address (factory setting = 22).
5. To verify the IO connection, open 'Interactive IO'
and send the *IDN? command to the 34401A by
selecting "Send & Read".
6. Use the 'Options' tab to increase the timeout period
for commands with execution times > 5 ms (e.g. *TST?).
Safety Summary
Do not defeat power cord safety ground feature. Plug
CAT II (300 v) IEC Measurement Category II. Inputs can be
in to a grounded (earthed) outlet. Do not use product in
any manner not specified by the manufacturer.
WARNING
Do not install substitute parts or perform any
unauthorized modification to the product. Return the
Main Power and Test Input Disconnect: Unplug
product to Agilent Technologies or a designated repair
product from wall outlet, remove power cord, and
center for service to ensure that safety features are
remove all probes from all terminals before servicing.
maintained.
Only qualified, service-trained personnel should
remove the cover from the instrument.
WARNING
Line and Current Protection Fuses: For continued
A WARNING notice denotes a hazard. It calls attention
protection against fire, replace the line fuse and the
to an operating procedure, practice, or the like that, if
current-protection fuse only with fuses of the specified
not correctly performed or adhered to, could result in
type and rating.
personal injury or death. Do not proceed beyond a
WARNING notice until the indicated conditions are fully
Front/Rear Switch: Do not change the position of the
understood and met.
Front/Rear switch on the front panel while signals are
present on either the front or rear set of terminals.
CAUTION
Switching while high voltages or currents are present
A CAUTION notice denotes a hazard. It calls attention
may cause instrument damage and lead to the risk of
to an operating procedure, practice, or the like that, if
electric shock.
not correctly performed or adhered to, could result in
IEC Measurement Category II. The HI and LO input
damage to the product or loss of important data. Do
terminals may be connected to mains under IEC
not proceed beyond a CAUTION notice until the
Measurement Category II overvoltage conditions for
indicated conditions are fully understood and met.
measurement of line voltages up to 300 VAC. To avoid
the danger of electric shock, do not connect the inputs
Symbols
to mains for line voltages above 300 VAC. Connect to
mains only at an outlet, or in a device connected to
Earth Ground
such an outlet, on a branch circuit protected by a circuit
breaker. See "Safety Notices" in the User's Guide for
further information.
Chassis Ground
Protection Limits: To avoid instrument damage and
the risk of electric shock, do not exceed any of the
protection limits indicated on the terminal panel and
Risk of electric shock
defined in the User's Guide.
ADDITIONAL SAFETY INFORMATION
Refer to manual for additional safety
For further information, refer to the "Safety Notices"
information.
section in the Agilent 34401A User's Guide.
Copyright © 2007 Agilent Technologies, Inc.
Printed In Malaysia
August 2007
E0807
34401-90005
Edition 1
Agilent 34401A
6½ Digit Multimeter
Quick Start Tutorial
connected to mains (up to 300 VAC) under
Category II overvoltage conditions.
1. Preparing for Use
Connect the Power Cord.
Then plug in the instrument.
Line voltage switch is set at factory for
country of destination – verify setting
before applying power.
Connect the Test Leads to the Input Terminals.
* Also used for capacitance,
continuity, diode test, freq-
uency, 2-wire resistance,
and 2-wire temperature
measurements.
Product Reference CD-ROM. All product documentation, software, and examples
are included on the Agilent 34401A Product Reference CD-ROM.
Adjust the Carry Handle.
Grasp the handle by the
sides and pull outward:
Then adjust the handle
to the desired position:
I
+
AC or DC
Voltage*
-
-
AC or
DC
Current
+
See "Safety Summary" on the back of this tutorial.