Memorise And Recall Program; Memorise A Program; Memorized Program Recall; Welding Programs Management - Lincoln Electric INVERTEC 175TP Operator's Manual

Hide thumbs Also See for INVERTEC 175TP:
Table of Contents

Advertisement

EN
7.0

MEMORISE AND RECALL PROGRAM

The generator allows you to memorize and subsequently recall up
30 welding programs.
7.1

MEMORISE A PROGRAM

1.
Set the process and the desired welding profile (as specified
in § 4.0 and 5.0);
2.
Press for more than three seconds the key 32 (entry in the
memorise state is accompanied by long "beep" and the first
memory location P01on the display );
3.
If you want to memorize the program in another memory lo-
cation, turn the encoder to the right (increasing the number of
memory location) to the memory location where you want to
memorize the program;
4.
Press for more than three seconds the key 32. At this point
the program is stored in desired memory location (the memo-
rise is accompanied by long "beep" and the text "MEM" on
the display).
The exit from this state is possible in three ways:
- Memorize of program;
- Inactivity of key 32 and encoder (10 seconds);
- Short press of key 32.
NOTE: THE MEMORY LOCATIONS CAN BE OVERWRITTEN.
DURING THE MEMORISE STATE ALL KEYS (WITH THE EX-
CEPTION OF THE KEY 32 AND THE ENCODER) ARE DIS-
ABLED AND THEREFORE YOU CAN NOT CHANGE ANY
PARAMETER.
7.2

MEMORIZED PROGRAM RECALL

1.
Press for more than three seconds the key 31 (entry in the re-
call program state is accompanied by long "beep" and the
first memory location P01on the display );
2.
Turn the encoder to the right (increasing the number of mem-
ory location) to the program memory location that you want
to recall;
3.
Press for more than three seconds the key 31. At this point
desired program is loaded (the recall is accompanied by long
"beep").
The exit from this state is possible in three ways:
- Recalling a program;
- Inactivity of key 31 and encoder (10 seconds);
- Short press of key 31.
NOTE: DURING THE RECALL STATE ALL KEYS (WITH THE
EXCEPTION OF THE KEY 31 AND THE ENCODER) ARE DIS-
MEMORISE AND RECALL PROGRAM
AUTOMATIC SEQUENCE
7 EN
ABLED AND THEREFORE YOU CAN NOT CHANGE ANY PA-
RAMETER.
8.0

WELDING PROGRAMS MANAGEMENT

The welding and the relative parameters set up can be done man-
ually through various commands.
When first switched on the generator is set up in a predefined
state and with welding parameters value that allows to work imme-
diately.
Moreover, the generator is provided with a memory that saves the
set up configuration for each welding mode (MMA, TIG HF, TIG
Lift) before it is turn off.
Therefore, the worker will be able to see the last set up when the
generator is switched on again.
9.0

THE USE OF THE REMOTE CONTROL

The power source allows the use of the remote
controls. After connecting the remote control to
the female connector on the front of the ma-
chine you can choose whether to work in local
or remote mode by means of vertical scroll key
(Ref. 14 - Picture 1 Page 3.) .
CAUTION: PRESSING VERTICAL SCROLL KEY (REF. 14 -
FIG. 1 PAGE 3) WHEN THE REMOTE CONTROL IS NOT CON-
NECTED HAS NO EFFECT.
In electrode welding mode, after activating the remote function
you can adjust welding current continuously from minimum to
maximum using the remote control. The display will show the cur-
rent set with the control.
NOTE: IN ELECTRODE MODE YOU CAN SELECT
MANUAL REMOTE CONTROL ONLY
In TIG welding mode you can select between two different remote
controls:
1.
Manual Remote Control:
this mode is especially useful in combination with remote
controls or RC-type torches, i.e. equipped with a knob or
slider to regulate current remotely. The welding current
will be adjustable continuously from minimum to maxi-
mum. To use this peripheral device properly and comfort-
ably selection of "four stroke" mode is recommended.