SHR-4081N/P USER'S MANUAL
Alarm Detection Setup
●
Sensor State
Off : Sensor does not operate.
① N.O(Normal Open) Sensor : Sensor remains open all the time and if closed,
➁ N.C(Normal Close) Sensor : Sensor remains closed all the time and if open,
Cam
●
Determines a camera which will synchronize with the current sensor.
The default is currently set to the sensor number. A sensor shall be synchronized
with at least a camera. Multi-synchronization is possible.
Alarm-Out
●
Arranges Alarm-Out when Alarm Sensor sounds.
At this moment, this supports 5 Alarm Outs. Choose an alarm-out that you want to
synchronize with the current sensor. Multi-choice is possible.
●
Duration
Determines Alarm-Out Duration. Alarm-Out continues for the determined duration.
Off / 3sec / 5sec / 10sec / 20sec / 30sec
5-21
English
an alarm will be issued. (A Contact)
an alarm will be issued. ( B Contact)
Motion Detection Setup
●
M.D State
Off : Motion Detection does not operate
On : Motion Detection starts operation.
●
Area
Select the Motion Detection zone. It is composed of 45x40(NTSC) / 45x48(PAL)
sized Block. You are forbidden to determine 4 block rows(Up/Down/Left/Right) to
allow them to be
displayed in all monitors.
Select All : Selects the whole area.
Select One : Selects a block every time. Selection is done by a toggle system.
Select Quarter : Split the whole area into 4 pieces, which enables selecting a
fourth of the whole area.
Clear All : Cancels the whole area.
Save & Exit : Saves and exits.
Exit : Exits without saving.