www.seagate.com
PowerChoice Supported Extended Power Condition Identifiers
Power Condition Identifiers
00
H
01 - 80
H
81
H
82
H
83
H
84 - FE
H
FF
H
1.2.6

Environmental limits

Temperature and humidity values experienced by the drive must be such that condensation does not occur on any
drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58.7°F (14.8°C).
NOTE
1.2.6.0.1
a. Operating
41°F to 158°F (5°C to 70°C) temperature range with a maximum temperature gradient of 36°F (20°C) per hour as reported by the
drive.
The maximum allowable drive reported temperature is 158°F (70°C).
Air flow may be required to achieve consistent nominal drive temperature values (see
required cooling is provided for the electronics and HDA, place the drive in its final mechanical configuration, and perform
random write/read operations. After the temperatures stabilize, monitor the current drive temperature using the SMART
temperature attribute 194 or Device Statistics log 04h page 5.
b. Non-operating
–40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assumes that
the drive is packaged in the shipping container designed by Seagate for use with drive.
1.2.6.1

Humidity

The values below assume that no condensation on the drive occurs. Maximum wet bulb temperature is 84.2°F (29°C).
1.2.6.1.1
Operating:
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
Nonoperating:
5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour.
1.2.6.1.2
Operating:
–304.8 m to 3048 m (–1000 ft. to 10,000+ ft.)
Nonoperating:
–304.8 m to 12,192 m (–1000 ft. to 40,000+ ft.)
Seagate SkyHawk Serial ATA Product Manual, Rev. B
Power Condition Name
Standby_z
Reserved
Idle_a
Idle_b
Idle_c
Reserved
All EPC Power Conditions
To maintain optimal performance drives should be run at nominal drive
temperatures and humidity.
See
Section 1.2.10, "Reliability"
requirements.
Temperature
Relative humidity
Effective Altitude (sea level)
for rated MTBF device operating condition
Drive specifications
Section
1.3.4). To confirm that the
14