21 . Remove and discard mating ring and seal (Fig . 19 .1).
22 . Carefully remove auger (Fig . 19 .2).
WARNING!
Use caution when removing auger. The auger is very
sharp - handle with care to avoid personal injury.
Evaporator Assembly
1 . Remove and inspect main housing O-ring seal. Replace if
damaged in any way.
2 . Clean O-ring groove. Lubricate O-ring with Petrol-gel and
reinstall.
3 . Use cardboard disc to press new mating ring into main
housing (Fig . 20 .1).
4 . Lube the shaft with liquid soap in the area shown
(Fig . 20 .2) and slip on seal and spring (Fig . 20 .3).
Note: Do not touch the sealing surfaces with bare hands.
Contact with bare skin will cause premature seal failure.
5 . Install auger (Fig . 20 .4).
6 . Install main housing:
§ Slide main housing onto auger shaft (Fig . 21 .1).
§ Install three M6x25 allen screws (Fig . 21 .2).
§ Connect vent line to T fitting (Fig . 21 .3).
Fig . 19
1
Fig . 20
1
Cardboard
disc
Do NOT
touch!
2
3
Fig . 21
3
2
15CI100A with Rear Drain
2
4
1
17